# Council Regulation (EEC) No 3821/85 of 20 December 1985 on recording equipment in road transport, Division 5.2.8: Faults data

Extent: E+W+S+N.I.

For the purpose of this subparagraph, time shall be recorded with a resolution of one second.
207 The driver card shall be able to store data related to the following faults detected by the recording equipment while the card was inserted:
card fault (where this card is the subject of the event),
recording equipment fault.
208 The driver card shall be able to store the following data for these faults:
fault code,
date and time of beginning of the fault (or of card insertion if the fault was on-going at that time),
date and time of end of the fault (or of card withdrawal if the fault was on-going at that time),
VRN and registering Member State of vehicle in which the fault happened.
209 The driver card shall be able to store data for the twelve most recent faults of each type (i.e. 24 faults).

---
Source: https://www.legislation.gov.uk/eur/1985/3821/annex/2/division/IV/division/5/division/5.2/division/5.2.8 (the official version)
Page: https://openlegislation.uk/eu-regulation-1985-3821/annex-2/division-IV/division-5/division-5.2/division-5.2.8