# Commission Regulation (EEC) No 2568/91 of 11 July 1991 on the characteristics of olive oil and olive-residue oil and on the relevant methods of analysis, Division 3.1.3.1

Extent: E+W+S+N.I.

Tube, made of a material inert to the substances to be analysed (usually glass or fused silica). The internal diameter shall be between 0,20 to 0,32 mm. The internal surface shall undergo an appropriate treatment (e.g. surface preparation, inactivation) before receiving the stationary phase coating. A length of 60 m is sufficient for fatty acid and cis and trans isomers of fatty acids.

---
Source: https://www.legislation.gov.uk/eur/1991/2568/annex/X/part/B/division/3/division/3.1/division/3.1.3/division/3.1.3.1 (the official version)
Page: https://openlegislation.uk/eu-regulation-1991-2568/annex-X/part-B/division-3/division-3.1/division-3.1.3/division-3.1.3.1
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.