Division 2.8 Removal of solvent and weighing of extract
United Kingdom
Remove the greater part of the solvent by distillation on an electrically heated bath. Remove the last traces of solvent by heating the flask in the oven at 103 ± 2° C for 20 minutes. Assist the elimination process either by blowing in air, or preferably an inert gas, at intervals or by using reduced pressure.
Leave the flask in a dessicator to cool for at least one hour and weigh to the nearest 1 mg.
Heat again for 10 minutes under the same conditions, cool in a dessicator and reweigh.
The difference between the two weighings shall not exceed 10 mg. If it does, heat again for periods of 10 minutes followed by cooling and weighing until the weight difference is 10 mg or less. Note the last weight of the flask.
Carry out duplicate determinations on the test sample.