Division A.3 Apparatus and Equipment
United Kingdom
Usual laboratory apparatus and in particular the following:
- A.3.1.
Analytical balance capable of reading 0,1 mg.
- A.3.2.
Thermometer, with ground glass joint, calibrated in tenths of a degree from 10 to 30 °C. This thermometer must be certified or checked against a certified thermometer.
- A.3.3.
Pyrex-glass pycnometer of approximately 100 ml capacity fitted with a removable ground-glass thermometer (A.3.2). The pycnometer has a side tube 25 mm in length and 1 mm (maximum) in internal diameter ending in a conical ground joint. Other pycnometers as described in ISO 3507, e.g. 50 ml may be used if appropriate.
- A.3.4.
A tare bottle of the same external volume (to within 1 ml) as the pycnometer and with a mass equal to the mass of the pycnometer filled with a liquid of density 1,01 (sodium chloride solution A.2.1).
- A.3.5.
Thermally insulated jacket that fits the body of the pycnometer exactly.