OpenLegislation

Division 10.1 Statistical results of the interlaboratory testF1

United Kingdom

Original text. Later amendments are not shown.

The following data were obtained from an international method performance study carried out to internationally agreed procedures (1) (2).

Year of interlaboratory test 2000
Number of laboratories 18
Number of samples 6
Samples A B C D E F
Number of laboratories retained after eliminating outliers 16 18 18 14 18 18
Number of outliers (laboratories) 2 4
Number of accepted results 32 36 36 28 36 36
Mean value x – (mg/L)

272*

241*

30

591*

641*

46 107 492
Repeatability standard deviation, s r (mg/l) 8,0 3,6 15,0 3,7 6,7 8,5
Repeatability relative standard deviation, RSDr (%) 3,1 11,8 2,4 8,0 6,2 1,7
Repeatability limit, r (mg/l) 23 10 42 10 19 24
Reproducibility standard deviation, s R (mg/l) 8,5 8,4 25,0 4,55 13,4 24,4
Reproducibility relative standard deviation, RSD R (%) 3,3 27,8 4,1 9,9 12,5 5,0
Reproducibility limit, R (mg/l) 24 23 70 13 38 68

Sample types:

A
  • Plum spirit; split level *

  • B
  • Rum I; blind duplicates

  • C
  • Rum II; split level *

  • D
  • Slivovitz; blind duplicates

  • E
  • Brandy; blind duplicates

  • F
  • Marc spirit; blind duplicates.

    1. (1)Division (1)
    2. (2)Division (2)

    Annotations

    Textual amendments

    F1

    Inserted by Commission Implementing Regulation (EU) 2016/635 of 22 April 2016 amending the Annex to Regulation (EC) No 2870/2000 as regards certain reference methods for the analysis of spirit drinks.