OpenLegislation

Division 9.1 Response factor (RF i ) calculationF1

United Kingdom

Original text. Later amendments are not shown.

The response factor is calculated as follows

RF i = (C i ∕ area or height i )*(area or height is ∕ C is )

where:

C i
  • is the concentration of trans-anethole in the standard solution A (4.5.1)

  • C is
  • is the concentration of internal standard in the standard solution B (4.5.2)

  • area i
  • is the area (or height) of the trans-anethole peak

  • area is
  • the area (or height) of the internal standard peak

  • RF i is calculated from the five samples of solution C (4.5.4).

    Annotations

    Textual amendments

    F1

    Inserted by Commission Regulation (EC) No 2091/2002 of 26 November 2002 amending Regulation (EC) No 2870/2000 laying down Community reference methods for the analysis of spirits drinks.