Division 9 Method performance characteristics (precision)F1
United Kingdom
Results of the interlaboratory test:
the following table gives the performance for recognition of presence or absence of chalcones in pastis and aniseed-flavoured spirits.
The following data were obtained from an international method performance study carried out to internationally agreed procedures.
Year of interlaboratory test 1998 Number of laboratories 14 Number of samples 11 Analyte chalcones Inconsistent results between the two duplicates, attributed to a sampling error
Samples A B C D E F Number of laboratories retained after eliminating outliers 14 14 14 14 14 13 Number of outliers (laboratories) — — — — — 1 f1 Number of accepted results 28 14 14 28 28 26 Number of results for presence of chalcones 28 14 14 0 28 0 Number of results for absence of chalcones 0 0 0 28 0 26 Percentage of correct results (%) 100 100 100 100 100 100 Samples G H I J K Number of laboratories retained after eliminating outliers 14 14 14 14 14 Number of outliers (laboratories) — — — — — Number of accepted results 28 14 14 28 28 Number of results for presence of chalcones 0 0 0 0 0 Number of results for absence of chalcone 28 14 14 28 28 Percentage of correct results (%) 100 100 100 100 100 Sample types:
Apastis, blind duplicates
B pastis, single sample
C pastis, single sample
D ‘ pastis ’ (not containing chalcones), blind duplicates
E ‘ pastis ’ (not containing chalcones), blind duplicates
F aniseed-flavoured liqueur (not containing chalcones), blind duplicates
G aniseed-flavoured liqueur (not containing chalcones), blind duplicates
H ouzo (not containing chalcones), single sample
I ouzo (not containing chalcones), single sample
J anis (not containing chalcones), blind duplicates
K ‘ pastis ’ (not containing chalcones), blind duplicates.
Annotations
Textual amendments
Footnotes
- f1
Inconsistent results between the two duplicates, attributed to a sampling error