# Commission Regulation (EC) No 2870/2000 of 19 December 2000 laying down Community reference methods for the analysis of spirits drinks, Division 8.5: Syringaldehyde

Extent: E+W+S+N.I.

Analyte
Syringaldehyde
Samples
Whisky
Brandy
Rum
Cognac 1
Bourbon
Cognac 2
No of laboratories participating
16
15
16
16
16
16
No of results accepted (laboratories)
13
13
13
12
14
13
Mean value (mg/l)
1,0
0,2
4,8
3,2
10,5
9,7
Repeatability standard deviation, s r (mg/l)
0,03
0,02
0,04
0,08
0,10
0,09
Repeatability relative standard deviation, RSD r (%)
2,6
8,1
0,8
2,6
0,9
0,9
Repeatability limit, r (mg/l)
(r = 2,8 × s r )
0,1
0,1
0,1
0,2
0,3
0,3
Reproducibility standard deviation, s R (mg/l)
0,08
0,07
0,23
0,19
0,39
0,43
Reproducibility relative standard deviation, RSD R (%)
8
33
5
6
4
4
Reproducibility limit, R (g/l)
(R = 2,8 × s R )
0,2
0,2
0,7
0,5
1,1
1,2

---
Source: https://www.legislation.gov.uk/eur/2000/2870/annex/division/X/division/8/division/8.5 (the official version)