OpenLegislation

Division B.2.2 Number of incremental samplesF1

United Kingdom

Original text. Later amendments are not shown.

The aggregate sample shall be at least 1 kg or 1 litre except where it is not possible, e.g. when the sample consists of 1 package or unit.

The minimum number of incremental samples to be taken from the lot or sublot shall be as given in Table 3.

In the case of bulk liquid products the lot or sublot shall be thoroughly mixed in so far as possible and in so far it does not affect the quality of the product, by either manual or mechanical means immediately prior to sampling. In this case, a homogeneous distribution of contaminants is assumed within a given lot or sublot. It is therefore sufficient to take three incremental samples from a lot or sublot to form the aggregate sample.

The incremental samples shall be of similar weight/volume. The weight/volume of an incremental sample shall be at least 100 grams or 100 millilitres, resulting in an aggregate sample of at least about 1 kg or 1 litre. Departure from this method shall be recorded in the record provided for under point B.1.8 of this Annex.

Table 1

Subdivision of lots into sublots for products traded in bulk consignments

Lot weight (ton) Weight or number of sublots
≥ 1 500 500 tonnes
> 300 and < 1 500 3 sublots
≥ 100 and ≤ 300 100 tonnes
< 100 —

Table 2

Subdivision of lots into sublots for other products

Lot weight (ton) Weight or number of sublots
≥ 15 15-30 tonnes
< 15 —

Table 3

Minimum number of incremental samples to be taken from the lot or sublot

Weight or volume of lot/sublot (in kg or litre) Minimum number of incremental samples to be taken
< 50 3
≥ 50 and ≤ 500 5
> 500 10

If the lot or sublot consists of individual packages or units, then the number of packages or units which shall be taken to form the aggregate sample is given in Table 4.

Table 4

Number of packages or units (incremental samples) which shall be taken to form the aggregate sample if the lot or sublot consists of individual packages or units

Number of packages or units in the lot/sublot Number of packages or units to be taken
≤ 25 at least 1 package or unit
26-100 about 5 %, at least 2 packages or units
> 100 about 5 %, at maximum 10 packages or units

The maximum levels for inorganic tin apply to the contents of each can, but for practical reasons it is necessary to use an aggregate sampling approach. If the result of the test for an aggregate sample of cans is less than but close to the maximum level of inorganic tin and if it is suspected that individual cans might exceed the maximum level, then it might be necessary to conduct further investigations.

Where it is not possible to carry out the method of sampling set out in this chapter because of the unacceptable commercial consequences (e.g. because of packaging forms, damage to the lot, etc.) or where it is practically impossible to apply the abovementioned method of sampling, an alternative method of sampling may be applied provided that it is sufficiently representative for the sampled lot or sublot and is fully documented.

Annotations

Textual amendments

F1

Substituted by Commission Regulation (EU) No 836/2011 of 19 August 2011 amending Regulation (EC) No 333/2007 laying down the methods of sampling and analysis for the official control of the levels of lead, cadmium, mercury, inorganic tin, 3-MCPD and benzo(a)pyrene in foodstuffs (Text with EEA relevance).

Notes on the whole EU Regulation

Textual amendments

F1