Division C.2.2.2 Specific procedures for polycyclic aromatic hydrocarbonsF1

United Kingdom

Original text. Later amendments are not shown.

The analyst shall ensure that samples do not become contaminated during sample preparation. Containers shall be rinsed with high purity acetone or hexane before use to minimise the risk of contamination. Wherever possible, apparatus and equipment coming into contact with the sample shall be made of inert materials such as aluminium, glass or polished stainless steel. Plastics such as polypropylene or PTFE shall be avoided because the analytes can adsorb onto these materials.

F2For the analysis of PAH in cocoa and cocoa derived products, the determination of the fat content is performed in accordance with AOAC Official method 963.15 for the determination of the fat content of cocoa beans and derived products. Equivalent fat determination procedures can be applied for which it can be demonstrated that the used fat determination procedure provides an equal (equivalent) fat content value.

Annotations

Textual amendments

F1

Substituted by Commission Regulation (EU) No 836/2011 of 19 August 2011 amending Regulation (EC) No 333/2007 laying down the methods of sampling and analysis for the official control of the levels of lead, cadmium, mercury, inorganic tin, 3-MCPD and benzo(a)pyrene in foodstuffs (Text with EEA relevance).

F2

Inserted by Commission Regulation (EU) 2016/582 of 15 April 2016 amending Regulation (EC) No 333/2007 as regards the analysis of inorganic arsenic, lead and polycyclic aromatic hydrocarbons and certain performance criteria for analysis (Text with EEA relevance).

Notes on the whole EU Regulation

Textual amendments

F1

Substituted by Commission Regulation (EU) 2016/582 of 15 April 2016 amending Regulation (EC) No 333/2007 as regards the analysis of inorganic arsenic, lead and polycyclic aromatic hydrocarbons and certain performance criteria for analysis (Text with EEA relevance).