  "url": "https://openlegislation.uk/eu-regulation-2008-1272/annex-I/division-2/division-2.11/division-2.11.2/division-2.11.2.2",
  "json_url": "https://openlegislation.uk/eu-regulation-2008-1272/annex-I/division-2/division-2.11/division-2.11.2/division-2.11.2.2.json",
  "legislation": "eur/2008/1272",
  "legislation_title": "Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006 (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2008-1272",
  "path": "annex/I/division/2/division/2.11/division/2.11.2/division/2.11.2.2",
  "kind": "division",
  "number": "2.11.2.2",
  "heading": "A self-heating substance or mixture shall be classified in one of the two categories for this class if, in a test performed in accordance with test method N.4 in Part III, sub-section 33.3.1.6 of the UN RTDG, Manual of Tests and Criteria, the result meets the criteria according to Table 2.11.1:",
  "text": "Table 2.11.1\nCriteria for self-heating substances and mixtures\nCategory\nCriteria\n1\nA positive result is obtained in a test using a 25 mm sample cube at 140 oC\n2\n(a) a positive result is obtained in a test using a 100 mm sample cube at 140 oC and a negative result is obtained in a test using a 25 mm cube sample at 140 oC and the substance or mixture is to be packed in packages with a volume of more than 3 m3; or\n(b) a positive result is obtained in a test using a 100 mm sample cube at 140 oC and a negative result is obtained in a test using a 25 mm cube sample at 140 oC, a positive result is obtained in a test using a 100 mm cube sample at 120 oC and the substance or mixture is to be packed in packages with a volume of more than 450 litres; or\n(c) a positive result is obtained in a test using a 100 mm sample cube at 140 oC and a negative result is obtained in a test using a 25 mm cube sample at 140 oC and a positive result is obtained in a test using a 100 mm cube sample at 100 oC.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "F",
      "label": "F1",
      "text": "Substituted by Commission Regulation (EU) No 487/2013 of 8 May 2013 amending, for the purposes of its adaptation to technical and scientific progress, Regulation (EC) No 1272/2008 of the European Parliament and of the Council on classification, labelling and packaging of substances and mixtures (Text with EEA relevance)."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2008/1272/annex/I/division/2/division/2.11/division/2.11.2/division/2.11.2.2",
    "retrieved_at": "2026-11-01T14:51:47.470832+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}