# Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006 (Text with EEA relevance), Division 2.6.4.4: Possible test methods for determining the flash point of flammable liquids are listed in Table 2.6.3.

Extent: E+W+S+N.I.

Table 2.6.3
Methods for determining the flash point of flammable liquids
European standards:
EN ISO 1516 as amended
Determination of flash/no flash — Closed cup equilibrium method
EN ISO 1523 as amended
Determination of flash point — Closed cup equilibrium method
EN ISO 2719 as amended
Determination of flash point — Pensky-Martens closed cup method
EN ISO 3679 as amended
Determination of flash point — Rapid equilibrium closed cup method
EN ISO 3680 as amended
Determination of flash/no flash — Rapid equilibrium closed cup method
EN ISO 13736 as amended
Petroleum products and other liquids — Determination of flash point — Abel closed cup method
National standards:
Association française de normalisation, AFNOR:
NF M07-036 as amended
Détermination du point d'éclair — Vase clos Abel-Pensky
(identical to DIN 51755)
Deutsches Institut für Normung
DIN 51755 (flash points below 65 C) as amended Prüfung von Mineralölen und anderen brennbaren Flüssigkeiten; Bestimmung des Flammpunktes im geschlossenen Tiegel, nach Abel-Pensky
(identical to NF M07-036)

---