Division 2.8.2.1 Any self-reactive substance or mixture shall be considered for classification in this class as a self-reactive substance or mixture unless:
United Kingdom
- (a)
they are explosives, according to the criteria given in 2.1;
- (b)
they are oxidising liquids or solids, according to the criteria given in 2.13 or 2.14, except that mixtures of oxidising substances, which contain 5 % or more of combustible organic substances shall be classified as self-reactive substances according to the procedure defined in 2.8.2.2;
- (c)
they are organic peroxides, according to the criteria given in 2.15;
- (d)
their heat of decomposition is less than 300 J/g; or
- (e)
their self-accelerating decomposition temperature (SADT) is greater than 75 oC for a 50 kg packagef1.
Annotations
Footnotes
- f1
-
See UN RTDG, Manual of Tests and Criteria, subsections 28.1, 28.2, 28.3 and Table 28.3.