Division 1 One year after this Regulation has come into force:
United Kingdom
- (a)
Power consumption in ‘off mode’:
Power consumption of equipment in any off-mode condition shall not exceed 1,00 W.
- (b)
Power consumption in ‘standby mode(s)’:
The power consumption of equipment in any condition providing only a reactivation function, or providing only a reactivation function and a mere indication of enabled reactivation function, shall not exceed 1,00 W.
The power consumption of equipment in any condition providing only information or status display, or providing only a combination of reactivation function and information or status display, shall not exceed 2,00 W.
- (c)
Availability of off mode and/or standby mode
Equipment shall, except where this is inappropriate for the intended use, provide off mode and/or standby mode, and/or another condition which does not exceed the applicable power consumption requirements for off mode and/or standby mode when the equipment is connected to the mains power source.