Division 1 The inspector shall:
United Kingdom
- (a)
select the appropriate size of jaw for the meshes to be measured;
- (b)
ensure that the jaws are clean;
- (c)
check that the gauge completes the self-test satisfactorily;
- (d)
select the measuring force to be applied as follows:
- (i)
for active gear:
-
20 N for mesh sizes < 35 mm,
-
50 N for mesh sizes ≥ 35 mm and < 55 mm,
-
125 N for mesh sizes ≥ 55 mm;
-
- (ii)
for passive gear:
-
10 N for all mesh sizes;
-
- (i)
- (e)
verify the jaw type setting. The default setting is ‘Normal’. If small or large jaws are used, the inspector shall enter the menu and change the jaw type setting accordingly.