# Commission Regulation (EC) No 692/2008 of 18 July 2008 implementing and amending Regulation (EC) No 715/2007 of the European Parliament and of the Council on type-approval of motor vehicles with respect to emissions from light passenger and commercial vehicles (Euro 5 and Euro 6) and on access to vehicle repair and maintenance information (Text with EEA relevance), Division 5.1.1: Temperature conditioning test

Extent: E+W+S+N.I.

In a dedicated temperature chamber, the canister(s) is (are) cycled between temperatures from – 15 °C to 60 °C, with 30 min of stabilisation at – 15 °C and 60 °C. Each cycle shall last 210 min as in Figure 3. The temperature gradient shall be as close as possible to 1 °C/min. No forced air flow should pass through the canister(s).
The cycle is repeated 50 times consecutively. In total, this operation will last 175 hours.

---