OpenLegislation

Division 4.1.3 Conditioning of the test track and wetting conditionF1

United Kingdom

Original text. Later amendments are not shown.

The test track surface shall be watered at least half an hour prior to testing in order to equalise the surface temperature and water temperature. External watering should be supplied continuously throughout testing. For the whole testing area, the water depth shall be 1,0 ± 0,5 mm, measured from the peak of the pavement.

The test track should then be conditioned by conducting at least 10 test runs with tyres not involved in the test programme at 90 km/h.

Annotations

Textual amendments

F1

Inserted by Commission Regulation (EU) No 228/2011 of 7 March 2011 amending Regulation (EC) No 1222/2009 of the European Parliament and of the Council with regard to the wet grip testing method for C1 tyres (Text with EEA relevance).