{
  "url": "https://openlegislation.uk/eu-regulation-2009-1283/annex-I",
  "json_url": "https://openlegislation.uk/eu-regulation-2009-1283/annex-I.json",
  "legislation": "eur/2009/1283",
  "legislation_title": "Council Regulation (EU) No 1283/2009 of 22 December 2009 amending Council Regulation (EC) No 329/2007 concerning restrictive measures against the Democratic People's Republic of Korea",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2009-1283",
  "path": "annex/I",
  "kind": "annex",
  "number": "I",
  "heading": null,
  "text": "‘ANNEX I\nGOODS AND TECHNOLOGY REFERRED TO IN ARTICLES 2 AND 3\nAll goods and technology listed in Annex I to Regulation (EC) No 428/2009.\nANNEX Ia\nGOODS AND TECHNOLOGY REFERRED TO IN ARTICLES 2 AND 3\nOther items, materials, equipment, goods and technology which could contribute to North Korea's nuclear-related, other weapons of mass destruction-related or ballistic missile-related programmes.\n1.\nUnless otherwise stated, reference numbers used in the column entitled “Description” refer to the descriptions of dual use items and technology set out in Annex I to Regulation (EC) No 428/2009.\n2.\nA reference number in the column entitled “Related item from Annex I to Regulation (EC) No 428/2009” means that the characteristics of the item described in the column “Description” lie outside the parameters set out in the description of the dual use entry referred to.\n3.\nDefinitions of terms between “single quotation marks” are given in a technical note to the relevant item.\n4.\nDefinitions of terms between “double quotation marks” can be found in Annex I to Regulation (EC) No 428/2009.\nGENERAL NOTES\n1.\nThe object of the prohibitions contained in this Annex should not be defeated by the export of any non-prohibited goods (including plants) containing one or more prohibited components when the prohibited component or components are the principal element of the goods and can feasibly be removed or used for other purposes.\nN.B.: In judging whether the prohibited component or components are to be considered the principal element, it is necessary to weigh the factors of quantity, value and technological know-how involved and other special circumstances which might establish the prohibited component or components as the principal element of the goods being procured.\n2.\nGoods specified in this Annex include both new and used goods.\nGENERAL TECHNOLOGY NOTE (GTN)\n(To be read in conjunction with Part C)\n1.\nThe sale, supply, transfer or export of “technology” which is “required” for the “development”, “production” or “use” of goods the sale, supply, transfer or export of which is prohibited in Part A (Goods) below, is prohibited in accordance with the provisions of Part B.\n2.\nThe “technology”“required” for the “development”, “production” or “use” of prohibited goods remains under prohibition even when applicable to non-prohibited goods.\n3.\nProhibitions do not apply to that “technology” which is the minimum necessary for the installation, operation, maintenance (checking) and repair of those goods which are not prohibited.\n4.\nProhibitions on “technology” transfer do not apply to information “in the public domain”, to “basic scientific research” or to the minimum necessary information for patent applications.\nA.\nGOODS\nNUCLEAR MATERIALS, FACILITIES, AND EQUIPMENT\nI.A0.\nGoods\nNo\nDescription\nRelated item from Annex I to Regulation (EC) No 428/2009\nI.A0.001\nHollow cathode lamps as follows:\na.. Iodine hollow cathode lamps with windows in pure silicon or quartz;\nb.. Uranium hollow cathode lamps.\nI.A0.002\nFaraday isolators in the wavelength range 500 nm – 650 nm\nI.A0.003\nOptical gratings in the wavelength range 500 nm – 650 nm\nI.A0.004\nOptical fibres in the wavelength range 500 nm – 650 nm coated with anti-reflecting layers in the wavelength range\n500 nm – 650 nm and having a core diameter greater than 0,4 mm but not exceeding 2 mm.\nI.A0.005\nNuclear reactor vessel components and testing equipment, other than those specified in 0A001, as follows:\na.. Seals;\nb.. Internal components;\nc.. Sealing, testing and measurement equipment.\n0A001\nI.A0.006\nNuclear detection systems, other than those specified in 0A001.j. or\n1A004.c., for detection, identification or quantification of radioactive materials or radiation of nuclear origin and specially designed components thereof.\nN.B: For personal equipment refer to I.A1.004 below.\n0A001.j.\n1A004.c.\nI.A0.007\nBellows-sealed valves other than those specified in 0B001.c.6., 2A226 or 2B350, made of aluminium alloy or stainless steel type 304, 304L or 316L.\n0B001.c.6.2A226\n2B350\nI.A0.008\nLaser mirrors, other than those specified in 6A005.e., consisting of substrates having a thermal expansion coefficient of 10-6 K-1 or less at 20 °C (e.g. fused silica or sapphire).\nNote: This item does not cover optical systems specially designed for astronomical applications, except if the mirrors contain fused silica.\n0B001.g.5.\n6A005.e.\nI.A0.009\nLaser lenses, other than those specified in 6A005.e.2, consisting of substrates having a thermal expansion coefficient of 10-6 K-1 or less at 20 °C (e.g. fused silica).\n0B001.g.\n6A005.e.2.\nI.A0.010\nPipes, piping, flanges, fittings made of, or lined with nickel, or nickel alloy containing more than 40 % nickel by weight, other than those specified in 2B350.h.1.\n2B350\nI.A0.011\nVacuum pumps other than those specified in 0B002.f.2. or 2B231, as follows:\na.. Turbo-molecular pumps having a flow-rate equal to or greater than 400 l/s;\nb.. Roots type vacuum roughing pumps having a volumetric aspiration flow-rate greater than 200 m3/h;\nc.. Bellows-sealed, scroll, dry compressor, and bellows-sealed, scroll, dry vacuum pumps.\n0B002.f.2.\n2B231\nI.A0.012\nShielded enclosures for the manipulation, storage and handling of radioactive substances (hot cells).\n0B006\nI.A0.013\n“Natural uranium” or “depleted uranium” or thorium in the form of metal, alloy, chemical compound or concentrate and any other material containing one or more of the foregoing, other than those specified in 0C001.\n0C001\nI.A0.014\nDetonation chambers having a capacity of explosion absorption of more than 2,5 kg TNT equivalent.\nSPECIAL MATERIALS AND RELATED EQUIPMENT\nI.A1.\nGoods\nNo\nDescription\nRelated item from Annex I to Regulation (EC) No 428/2009\nI.A1.001\nBis(2-ethylhexyl) phosphoric acid (HDEHP or D2HPA) Chemical Abstract Number (CAS): [CAS 298-07-7] solvent in any quantity, with a purity greater than 90 %.\nI.A1.002\nFluorine gas CAS: [7782-41-4], with a purity of at least 95 %.\nI.A1.003\nRing-shaped seals and gaskets, having an inner diameter of 400 mm or less, made of any of the following materials:\na.. Copolymers of vinylidene fluoride having 75 % or more beta crystalline structure without stretching;\nb.. Fluorinated polyimides containing 10 % by weight or more of combined fluorine;\nc.. Fluorinated phosphazene elastomers containing 30 % by weight or more of combined fluorine;\nd.. Polychlorotrifluoroethylene (PCTFE, e.g. Kel-F ®);\ne.. Fluoro-elastomers (e.g., Viton ®, Tecnoflon ®);\nf.. Polytetrafluoroethylene (PTFE).\n1A001\nI.A1.004\nPersonal equipment for detecting radiation of nuclear origin, other than that specified in 1A004.c., including personal dosimeters.\n1A004.c.\nI.A1.005\nElectrolytic cells for fluorine production, other than those specified in 1B225, with an output capacity greater than 100 g of fluorine per hour.\n1B225\nI.A1.006\nCatalysts, other than those specified in 1A225 or 1B231, containing platinum, palladium or rhodium, usable for promoting the hydrogen isotope exchange reaction between hydrogen and water for the recovery of tritium from heavy water or for the production of heavy water.\n1A225\n1B231\nI.A1.007\nAluminium and its alloys, other than those specified in 1C002.b.4. or 1C202.a, in crude or semi-fabricated form having either of the following characteristics:\na.. “Capable of” an ultimate tensile strength of 460 MPa or more at 293 K (20 °C); or\nb.. Having a tensile strength of 415 MPa or more at 298 K (25 °C).\nTechnical note:\nThe phrase alloys “capable of” encompasses alloys before or after heat treatment.\n1C002.b.4.\n1C202.a.\nI.A1.008\nMagnetic metals, of all types and of whatever form, other than those specified in 1C003.a. having an “initial relative permeability” of 120 000 or more and a thickness between 0,05 mm and 0,1 mm.\nTechnical note:\nMeasurement of “initial relative permeability” must be performed on fully annealed materials.\n1C003.a.\nI.A1.009\n“Fibrous or filamentary materials” or prepregs, other than those specified in 1C010.a., 1C010.b., 1C210.a. or 1C210.b. as follows:\na.. Aramid “fibrous or filamentary materials” having either of the following characteristics:\n1.A “specific modulus” exceeding 10 × 106 m; or\n2.A “specific tensile strength” exceeding 17 × 104 m;\nb.. Glass “fibrous or filamentary materials” having either of the following characteristics:\n1.A “specific modulus” exceeding 3,18 × 106 m; or\n2.A “specific tensile strength” exceeding 76,2 × 103 m;\nc.. Thermoset resin-impregnated continuous “yarns”, “rovings”, “tows” or “tapes” with a width of 15 mm or less (once prepregs), made from glass “fibrous or filamentary materials” other than those specified in I.A1.010.a. below.\nd.. Carbon “fibrous or filamentary materials”;\ne.. Thermoset resin-impregnated continuous “yarns”, “rovings”, “tows”, or “tapes”, made from carbon “fibrous or filamentary materials”;\nf.. Polyacrylonitrile (PAN) continuous “yarns”, “rovings”, “tows” or “tapes”.\ng.. Para-aramid “fibrous or filamentary materials” (Kevlar® and other Kevlar®-like fibres).\n1C010.a.\n1C010.b.\n1C210.a.\n1C210.b.\nI.A1.010\nResin-impregnated or pitch-impregnated fibres (prepregs), metal or carbon-coated fibres (preforms) or “carbon fibre preforms”, as follows:\na.. Made from “fibrous or filamentary materials” specified in I.A1.009 above;\nb.. Epoxy resin “matrix” impregnated carbon “fibrous or filamentary materials” (prepregs), specified in 1C010.a., 1C010.b. or 1C010.c., for the repair of aircraft structures or laminates, of which the size of individual sheets does not exceed 50 cm × 90 cm;\nc.. Prepregs specified in 1C010.a., 1C010.b. or 1C010.c., when impregnated with phenolic or epoxy resins having a glass transition temperature (Tg) less than 433 K (160 °C) and a cure temperature lower than the glass transition temperature.\n1C010\n1C210\nI.A1.011\nReinforced silicon carbide ceramic composites usable for nose tips, re-entry vehicles, nozzle flaps, usable in “missiles”, other than those specified in 1C107.\n1C107\nI.A1.012\nNot used\nI.A1.013\nTantalum, tantalum carbide, tungsten, tungsten carbide and alloys thereof, other than those specified in 1C226, having both of the following characteristics:\na.. In forms having a hollow cylindrical or spherical symmetry (including cylinder segments) with an inside diameter between 50 mm and 300 mm; and\nb.. A mass greater than 5 kg.\n1C226\nI.A1.014\n“Elemental powders” of cobalt, neodymium or samarium or alloys or mixtures thereof containing at least 20 % by weight of cobalt, neodymium or samarium, with a particle size less than 200 μm.\nTechnical note:\n“Elemental powder” means a high purity powder of one element.\nI.A1.015\nPure tributyl phosphate (TBP) [CAS No 126-73-8] or any mixture having a TBP content of more than 5 % by weight.\nI.A1.016\nMaraging steel, other than those specified by 1C116 or 1C216.\nTechnical notes:\n1.\nThe phrase maraging steel “capable of” encompasses maraging steel before or after heat treatment.\n2.\nMaraging steels are iron alloys generally characterised by high nickel, very low carbon content and the use of substitutional elements or precipitates to produce strengthening and age-hardening of the alloy.\n1C116\n1C216\nI.A1.017\nMetals, metal powders and material as follows:\na.. Tungsten and tungsten alloys, other than those specified in 1C117, in the form of uniform spherical or atomized particles of 500 μm (micrometre) diameter or less with a tungsten content of 97 % by weight or more;\nb.. Molybdenum and molybdenum alloys, other than those specified in 1C117, in the form of uniform spherical or atomized particles of 500 μm diameter or less with a molybdenum content of 97 % by weight or more;\nc.. Tungsten materials in the solid form, other than those specified in 1C226 having material compositions as follows:\n1.. Tungsten and alloys containing 97 % by weight or more of tungsten;\n2.. Copper infiltrated tungsten containing 80 % by weight or more of tungsten; or\n3.. Silver infiltrated tungsten containing 80 % by weight or more of tungsten.\n1C117\n1C226\nI.A1.018\nSoft magnetic alloys, other than those specified in 1C003, having a chemical composition as follows:\na Iron content between 30 % and 60 %; and\nb Cobalt content between 40 % and 60 %.\n1C003\nI.A1.019\nNot used\nI.A1.020\nGraphite, other than that specified in 0C004 or 1C107.a, designed or specified for use in Electrical Discharge Machining (EDM) machines\n0C004\n1C107a\nMATERIALS PROCESSING\nI.A2.\nGoods\nManufacturers calculating positioning accuracy in accordance with ISO 230/2 (1997) should consult the competent authorities of the Member State in which they are established.\nNo\nDescription\nRelated item from Annex I to Regulation (EC) No 428/2009\nI.A2.001\nVibration test systems, equipment and components thereof, other than those specified in 2B116:\na.. Vibration test systems employing feedback or closed loop techniques and incorporating a digital controller, capable of vibrating a system at an acceleration equal to or greater than 0,1 g rms between 0,1 Hz and 2 kHz and imparting forces equal to or greater than 50 kN, measured “bare table”;\nb.. Digital controllers, combined with specially designed vibration test “software”, with a “real-time control bandwidth” greater than 5 kHz designed for use with vibration test systems specified in a.;\nTechnical note:\n“Real-time control bandwidth” is defined as the maximum rate at which a controller can execute complete cycles of sampling, processing data and transmitting control signals.\nc.. Vibration thrusters (shaker units), with or without associated amplifiers, capable of imparting a force equal to or greater than 50 kN, measured “bare table”, and usable in vibration test systems specified in a.;\nd.. Test piece support structures and electronic units designed to combine multiple shaker units in a system capable of providing an effective combined force equal to or greater than 50 kN, measured “bare table”, and usable in vibration systems specified in a.\nTechnical note:\n“bare table” means a flat table, or surface, with no fixture or fittings.\n2B116\nI.A2.002\nMachine tools, other than those specified in 2B001.c. or 2B201.b., for grinding having positioning accuracies with “all compensations available” equal to or less (better) than 15 μm according to ISO 230/2 (1988) or national equivalents along any linear axis.\n2B001.c.\n2B201.b.\nI.A2.002a\nComponents and numerical controls, specially designed for machine tools specified in 2B001, 2B201, or I.A2.002 above.\nI.A2.003\nBalancing machines and related equipment as follows:\na.. Balancing machines, designed or modified for dental or other medical equipment, having all the following characteristics:\n1.. Not capable of balancing rotors/assemblies having a mass greater than 3 kg;\n2.. Capable of balancing rotors/assemblies at speeds greater than 12 500 rpm;\n3.. Capable of correcting unbalance in two planes or more; and\n4.. Capable of balancing to a residual specific unbalance of 0,2 g × mm per kg of rotor mass;\nb.. “Indicator heads” designed or modified for use with machines specified in a. above.\nTechnical note:\n“Indicator heads” are sometimes known as balancing instrumentation.\n2B119\nI.A2.004\nRemote manipulators that can be used to provide remote actions in radiochemical separation operations or hot cells, other than those specified in 2B225, having either of the following characteristics:\na.. A capability of penetrating a hot cell wall of 0,3 m or more (through the wall operation); or\nb.. A capability of bridging over the top of a hot cell wall with a thickness of 0,3 m or more (over the wall operation).\nTechnical note:\nRemote manipulators provide translation of human operator actions to a remote operating arm and terminal fixture. They may be of master/slave type or operated by joystick or keypad.\n2B225\nI A2.005\nControlled atmosphere heat treatment furnaces or oxidation furnaces capable of operation at temperatures above 400 °C\nNote: This item does not cover tunnel kilns with roller or car conveyance, tunnel kilns with conveyor belt, pusher type kilns or shuttle kilns, specially designed for the production of glass, tableware ceramics or structural ceramics.\n2B226\n2B227\nI.A2.006\nNot used\nI.A2.007\n“Pressure transducers”, other than those defined in 2B230, capable of measuring absolute pressures at any point in the range 0 to 200 kPa and having both of the following characteristics:\na.. Pressure sensing elements made of or protected by “Materials resistant to corrosion by uranium hexafluoride (UF6)”, and\nb.. Having either of the following characteristics:\n1.. A full scale of less than 200 kPa and an “accuracy” of better than ± 1 % of full scale; or\n2.. A full scale of 200 kPa or greater and an “accuracy” of better than 2 kPa.\nTechnical note:\nFor the purposes of 2B230, “accuracy” includes non-linearity, hysteresis and repeatability at ambient temperature.\n2B230\nI.A2.008\nLiquid-liquid contacting equipment (mixer-settlers, pulsed columns, centrifugal contactors); and liquid distributors, vapour distributors or liquid collectors designed for such equipment, where all surfaces that come in direct contact with the chemical(s) being processed are made from any of the following materials:\na.. Alloys with more than 25 % nickel and 20 % chromium by weight;\nb.. Fluoropolymers;\nc.. Glass (including vitrified or enamelled coating or glass lining);\nd.. Graphite or “carbon graphite”;\ne.. Nickel or alloys with more than 40 % nickel by weight;\nf.. Tantalum or tantalum alloys;\ng.. Titanium or titanium alloys;\nh.. Zirconium or zirconium alloys; or\ni.. Stainless steel.\nTechnical note:\n“Carbon graphite” is a composition consisting of amorphous carbon and graphite, in which the graphite content is 8 % or more by weight.\n2B350.e.\nI.A2.009\nIndustrial equipment and components, other than those specified in 2B350.d., as follows:\nHeat exchangers or condensers with a heat transfer surface area greater than 0,05 m2, and less than 30 m2; and tubes, plates, coils or blocks (cores) designed for such heat exchangers or condensers, where all surfaces that come in direct contact with the fluid(s) are made from any of the following materials:\na.. Alloys with more than 25 % nickel and 20 % chromium by weight;\nb.. Fluoropolymers;\nc.. Glass (including vitrified or enamelled coating or glass lining);\nd.. Graphite or “carbon graphite”;\ne.. Nickel or alloys with more than 40 % nickel by weight;\nf.. Tantalum or tantalum alloys;\ng.. Titanium or titanium alloys;\nh.. Zirconium or zirconium alloys;\ni.. Silicon carbide;\nj.. Titanium carbide; or\nk.. Stainless steel.\nNote: This item does not cover vehicle radiators.\nTechnical note:\nThe materials used for gaskets and seals and other implementation of sealing functions do not determine the status of control of the heat exchanger.\n2B350.d.\nI.A2.010\nMultiple-seal, and seal-less pumps, other than those specified in 2B350.i, suitable for corrosive fluids, with manufacturer's specified maximum flow-rate greater than 0,6 m3/hour, or vacuum pumps with manufacturer's specified maximum flow-rate greater than 5 m3/hour [measured under standard temperature (273 K or 0 °C) and pressure (101,3 kPa) conditions]; and casings (pump bodies), preformed casing liners, impellers, rotors or jet pump nozzles designed for such pumps, in which all surfaces that come in direct contact with the chemical(s) being processed are made from any of the following materials:\na.. Alloys with more than 25 % nickel and 20 % chromium by weight;\nb.. Ceramics;\nc.. Ferrosilicon;\nd.. Fluoropolymers;\ne.. Glass (including vitrified or enamelled coatings or glass lining);\nf.. Graphite or “carbon graphite”;\ng.. Nickel or alloys with more than 40 % nickel by weight;\nh.. Tantalum or tantalum alloys;\ni.. Titanium or titanium alloys;\nj.. Zirconium or zirconium alloys;\nk.. Niobium (columbium) or niobium alloys;\nl.. Stainless Steel; or\nm.. Aluminium Alloys.\nTechnical note:\nThe materials used for gaskets and seals and other implementation of sealing functions do not determine the status of control of the pump.\n2B350.i.\nI.A2.011\n“Centrifugal separators”, other than those specified in 2B352.c., capable of continuous separation without the propagation of aerosols and manufactured from:\na.. Alloys with more than 25 % nickel and 20 % chromium by weight;\nb.. Fluoropolymers;\nc.. Glass (including vitrified or enamelled coating or glass lining);\nd.. Nickel or alloys with more than 40 % nickel by weight;\ne.. Tantalum or tantalum alloys;\nf.. Titanium or titanium alloys; or\ng.. Zirconium or zirconium alloys.\nTechnical note:\n“Centrifugal separators” include decanters.\n2B352.c.\nI.A2.012\nSintered metal filters, other than those specified in 2B352.d., made of nickel or nickel alloy with more than 40 % nickel by weight.\n2B352.d.\nI.A2.013\nSpin-forming machines and flow-forming machines, other than those specified by 2B009, 2B109 or 2B209 and specially designed components therefor.\nTechnical note:\nFor the purpose of this item, machines combining the functions of spin-forming and flow-forming are regarded as flow-forming machines.\n2B009\n2B109\n2B209\nELECTRONICS\nI.A3.\nGoods\nNo\nDescription\nRelated item from Annex I to Regulation (EC) No 428/2009\nI.A3.001\nHigh voltage direct current power supplies, other than those specified in 0B001.j.5. or 3A227, having both of the following characteristics:\na.. Capable of continuously producing, over a time period of eight hours, 10 kV or more, with output power of 5 kW or more with or without sweeping; and\nb.. Current or voltage stability better than 0,1 % over a time period of four hours.\n0B001.j.5.\n3A227\nI.A3.002\nMass spectrometers, other than those specified in 0B002.g or 3A233, capable of measuring ions of 200 atomic mass units or more and having a resolution of better than 2 parts in 200, as follows, and ion sources therefor:\na.. Inductively coupled plasma mass spectrometers (ICP/MS);\nb.. Glow discharge mass spectrometers (GDMS);\nc.. Thermal ionisation mass spectrometers (TIMS);\nd.. Electron bombardment mass spectrometers which have a source chamber constructed from, lined with or plated with “materials resistant to corrosion by uranium hexafluoride UF6”;\ne.. Molecular beam mass spectrometers having either of the following characteristics:\n1.. A source chamber constructed from, lined with or plated with stainless steel or molybdenum and equipped with a cold trap capable of cooling to 193 K (– 80 °C) or less; or\n2.. A source chamber constructed from, lined with or plated with materials resistant to UF6;\nf.. Mass spectrometers equipped with a micro-fluorination ion source designed for actinides or actinide fluorides.\n0B002.g\n3A233\nI.A3.003\nFrequency changers or generators, other than those specified by 0B001.b.13 or3A225, having all of the following characteristics, and specially designed components and software therefor:\na.. Multiphase output capable of providing a power of 40 W or greater;\nb.. Capable of operating in the frequency range between 600 and 2 000 Hz; and\nc.. Frequency control better (less) than 0,1 %.\nTechnical notes:\n1.\nFrequency changers are also known as converters, inverters, generators, electronic test equipment, AC power supplies, variable speed motor drives or variable frequency drives.\n2.\nThe functionality specified in this item may be met by certain equipment marketed as; electronic test equipment, AC power supplies, variable speed motor drives or variable frequency drives.\n0B001.b.13.\n3A225\nI.A3.004\nSpectrometers and diffractometers, designed for the indicative test or quantitative analysis of the elemental composition of metals or alloys without chemical decomposition of the material.\nSENSORS AND LASERS\nI.A6.\nGoods\nNo\nDescription\nRelated item from Annex I to Regulation (EC) No 428/2009\nI.A6.001\nYttrium aluminium garnet (YAG) rods.\nI.A6.002\nOptical equipment and components, other than those specified in 6A002 or 6A004.b as follows:\nInfrared optics in the wavelength range 9 μm – 17 μm and components thereof, including cadmium telluride (CdTe) components.\n6A002\n6A004.b.\nI.A6.003\nWave front corrector systems, other than mirrors specified in 6A004.a, 6A005.e or 6A005.f., for use with a laser beam having a diameter exceeding 4 mm, and specially designed components thereof, including control systems, phase front sensors and “deformable mirrors” including bimorph mirrors.\n6A004.a.\n6A005.e.\n6A005.f.\nI.A6.004\nArgon ion “lasers”, other than those specified in 0B001.g.5, 6A005 and or 6A205.a., having an average output power equal to or greater than 5 W.\n0B001.g.5.\n6A005.a.6.\n6A205.a.\nI.A6.005\nSemiconductor “lasers”, other than those specified in 0B001.g.5., 0B001.h.6. or 6A005.b., and components thereof, as follows:\na.. Individual semiconductor “lasers” with an output power greater than 200 mW each, in quantities larger than 100;\nb.. Semiconductor “laser” arrays having an output power greater than 20 W.\nNotes:\n1.\nSemiconductor “lasers” are commonly called “laser” diodes.\n2.\nThis item does not cover “laser” diodes with a wavelength in the range 1,2 μm – 2,0 μm.\n0B001.g.5.\n0B001.h.6.\n6A005.b.\nI.A6.006\nTunable semiconductor “lasers” and tunable semiconductor “laser” arrays, other than those specified in 0B001.h.6. or 6A005.b., of a wavelength between 9 μm and 17 μm, as well as array stacks of semiconductor “lasers” containing at least one tunable semiconductor “laser” array of such wavelength.\nNote:\nSemiconductor “lasers” are commonly called “laser” diodes.\n0B001.h.6.\n6A005.b.\nI.A6.007\nSolid state “tunable”“lasers”, other than those specified in 0B001.g.5., 0B001.h.6. or 6A005.c.1., and specially designed components thereof as follows:\na.. Titanium-sapphire lasers,\nb.. Alexandrite lasers.\n0B001.g.5.\n0B001.h.6.\n6A005.c.1.\nI.A6.008\nNeodymium-doped (other than glass) “lasers”, other than those specified in 6A005.c.2.b., having an output wavelength greater than 1,0 μm but not exceeding 1,1 μm and output energy exceeding 10 J per pulse.\n6A005.c.2.b.\nI.A6.009\nComponents of acousto-optics, as follows:\na.. Framing tubes and solid-state imaging devices having a recurrence frequency equal to or exceeding 1 kHz;\nb.. Recurrence frequency supplies;\nc.. Pockels cells.\n6A203.b.4.\nI.A6.010\nRadiation-hardened cameras, or lenses thereof, other than those specified in 6A203.c., specially designed, or rated as radiation-hardened, to withstand a total radiation dose greater than 50 × 103 Gy(silicon) (5 × 106 rad (silicon)) without operational degradation.\nTechnical note:\nThe term Gy(silicon) refers to the energy in Joules per kilogram absorbed by an unshielded silicon sample when exposed to ionising radiation.\n6A203.c.\nI.A6.011\nTunable pulsed dye laser amplifiers and oscillators, other than those specified in 0B001.g.5, 6A005 and or 6A205.c., having all of the following characteristics:\na.. Operating at wavelengths between 300 nm and 800 nm;\nb.. An average output power greater than 10 W but not exceeding 30 W;\nc.. A repetition rate greater than 1 kHz; and\nd.. Pulse width less than 100 ns.\nNote:\nThis item does not cover single mode oscillators.\n0B001.g.5.\n6A005\n6A205.c.\nI.A6.012\nPulsed carbon dioxide “lasers”, other than those specified in, 0B001.h.6., 6A005.d. or 6A205.d., having all of the following characteristics:\na.. Operating at wavelengths between 9, μm and 11 μm;\nb.. A repetition rate greater than 250 Hz;\nc.. An average output power greater than 100 W but not exceeding 500 W; and\nd.. Pulse width less than 200 ns.\n0B001.h.6.\n6A005.d.\n6A205.d.\nNAVIGATION AND AVIONICS\nI.A7.\nGoods\nNo\nDescription\nRelated item from Annex I to Regulation (EC) No 428/2009\nI.A7.001\nInertial navigation systems and specially designed components thereof, as follows:\na.. Inertial navigation systems which are certified for use on “civil aircraft” by civil authorities of a State participating in the Wassenaar Arrangement, and specially designed components thereof, as follows:\n1.. Inertial navigation systems (INS) (gimballed or strapdown) and inertial equipment designed for “aircraft”, land vehicle, vessels (surface or underwater) or “spacecraft” for attitude, guidance or control, having any of the following characteristics, and specially designed components thereof:\na.. Navigation error (free inertial) subsequent to normal alignment of 0,8 nautical mile per hour (nm/hr) “Circular Error Probable” (CEP) or less (better); or\nb.. Specified to function at linear acceleration levels exceeding 10 g;\n2.. Hybrid Inertial Navigation Systems embedded with Global Navigation Satellite Systems(s) (GNSS) or with “Data-Based Referenced Navigation” (“DBRN”) System(s) for attitude, guidance or control, subsequent to normal alignment, having an INS navigation position accuracy, after loss of GNSS or “DBRN” for a period of up to four minutes, of less (better) than 10 metres “Circular Error Probable” (CEP);\n3.. Inertial Equipment for Azimuth, Heading, or North Pointing having any of the following characteristics, and specially designed components thereof:\na.. Designed to have an Azimuth, Heading, or North Pointing accuracy equal to, or less (better) than 6 arc minutes RMS at 45 degrees latitude; or\nb.. Designed to have a non-operating shock level of at least 900 g at a duration of at least 1 msec.\nb.. Theodolite systems incorporating inertial equipment specially designed for civil surveying purposes and designed to have an Azimuth, Heading, or North Pointing accuracy equal to, or less (better) than 6 arc minutes RMS at 45 degrees latitude, and specially designed components thereof.\nc.. Inertial or other equipment using accelerometers specified in 7A001 or 7A101, where such accelerometers are specially designed and developed as MWD (Measurement While Drilling) sensors for use in down-hole well services operations.\nNote: The parameters of a.1. and a.2. are applicable with any of the following environmental conditions:\n1.. Input random vibration with an overall magnitude of 7,7 g rms in the first half hour and a total test duration of one and a half hours per axis in each of the three perpendicular axes, when the random vibration meets the following:\na.. A constant power spectral density (PSD) value of 0,04 g2/Hz over a frequency interval of 15 to 1 000 Hz; and\nb.. The PSD attenuates with a frequency from 0,04 g2/Hz to 0,01 g2/Hz over a frequency interval from 1 000 to 2 000 Hz;\n2.. A roll and yaw rate equal to or greater than +2,62 radian/s (150 deg/s); or\n3.. According to national standards equivalent to 1. or 2. above.\nTechnical notes:\n1.\na.2. refers to systems in which an INS and other independent navigation aids are built into a single unit (embedded) in order to achieve improved performance.\n2.\n“Circular Error Probable” (CEP) – In a circular normal distribution, the radius of the circle containing 50 percent of the individual measurements being made, or the radius of the circle within which there is a 50 percent probability of being located.\n7A001\n7A003\n7A101\n7A103\nAEROSPACE AND PROPULSION\nI.A9.\nGoods\nNo\nDescription\nRelated item from Annex I to Regulation (EC) No 428/2009\nI.A9.001\nExplosive bolts.\nB.\nSOFTWARE\nNo\nDescription\nRelated item from Annex I to Regulation (EC) No 428/2009\nI.B.001\nSoftware required for the development, production or use of the items in Part A. (Goods).\nC.\nTECHNOLOGY\nNo\nDescription\nRelated item from Annex I to Regulation (EC) No 428/2009\nI.C.001\nTechnology required for the development, production or use of the items in Part A. (Goods).\n’",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "Manufacturers calculating positioning accuracy in accordance with ISO 230/2 (1997) should consult the competent authorities of the Member State in which they are established."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2009/1283/annex/I",
    "retrieved_at": "2026-11-01T14:51:00.823815+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}