OpenLegislation

Division 9.2 Incremental samplesF1F2

United Kingdom

Original text. Later amendments are not shown.

Incremental samples must be taken at random throughout the whole sampled portion and they must be of approximately equal sizes.

The incremental sample size is at least 100 grams or 25 grams in case of roughage or forage with low specific gravity.

In case that in accordance with the rules for the sampling procedure established in point 8 less than 40 incremental samples have to be taken, the size of the incremental samples shall be determined in function of the required size of the aggregate sample to be achieved (see point (6).

In case of sampling of small lots of packaged feed where according to the quantitative requirements a limited number of incremental samples have to be taken, an incremental sample shall be the contents of one original unit whose contents do not exceed 1 kg or one litre.

In case of sampling of packaged feed composed of small units (e.g. < 250 g), the size of the incremental sample depends on the size of the unit.

  1. 9.2.1Loose feed
  2. 9.2.2Packaged feed
  3. 9.2.3Homogeneous or homogenisable liquid or semi-liquid feed
  4. 9.2.4Non-homogenisable, liquid or semi-liquid feed
  5. 9.2.5Feed blocks and mineral licks

Annotations

Textual amendments

F1

Substituted by Commission Regulation (EU) No 691/2013 of 19 July 2013 amending Regulation (EC) No 152/2009 as regards methods of sampling and analysis (Text with EEA relevance).

F2

Words in Annex 1 point 8.2.2 substituted (31.12.2020) by The Animal Feed (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/654), regs. 1, 88(d)(i); 2020 c. 1, Sch. 5 para. 1(1)