  "url": "https://openlegislation.uk/eu-regulation-2009-152/annex-III/division-M/division-5/division-5.1",
  "json_url": "https://openlegislation.uk/eu-regulation-2009-152/annex-III/division-M/division-5/division-5.1.json",
  "legislation": "eur/2009/152",
  "legislation_title": "Commission Regulation (EC) No 152/2009 of 27 January 2009 laying down the methods of sampling and analysis for the official control of feed (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2009-152",
  "path": "annex/III/division/M/division/5/division/5.1",
  "kind": "division",
  "number": "5.1",
  "heading": null,
  "text": "Put the crucible into the calibrated muffle furnace set at 550 oC. Keep at this temperature until white, light grey or reddish ash is obtained which appears to be free from carbonaceous particles. Place the crucible in a desiccator, leave to cool and weigh immediately.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2009/152/annex/III/division/M/division/5/division/5.1",
    "retrieved_at": "2026-11-01T14:51:38.610873+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}