# Commission Regulation (EC) No 152/2009 of 27 January 2009 laying down the methods of sampling and analysis for the official control of feed (Text with EEA relevance), Division 5.6.3.3: Vitamin A working standard solution

Extent: E+W+S+N.I.

Pipette 3,0 ml of the undiluted vitamin A working standard solution, prepared according to 5.6.1 into a 50 ml graduated flask (4.2.2) and make up to the mark with 2-propanol (3.8). Pipette 5,0 ml of this solution into a 25 ml graduated flask and make up to the mark with 2-propanol (3.8). The nominal concentration of this solution is 6,72 IU vitamin A per ml. Measure the UV spectrum of this solution against 2-propanol (3.8) in the spectrophotometer (4.6) between 300 nm and 400 nm. The extinction maximum must be between 325 nm and 327 nm.
Calculation of the vitamin A content:
IU vitamin A/ml = E325 × 18,3
(E1 %1 cm for vitamin A alcohol = 1 821 at 325 nm in 2-propanol)

---