Division 5.6.1.2 Preparation of the calibration solutions and calibration graph
United Kingdom
Transfer 1,0, 2,0, 4,0 and 10,0 ml of the working standard solution into a series of 20 ml graduated flasks, make up to the mark with methanol (3.3) and mix. The nominal concentrations of these solutions are 2,5, 5,0, 10,0 and 25,0 μg/ml DL-α-tocopherol acetate, i.e. 2,28, 4,55, 9,1 μg/ml and 22,8 μg/ml DL-α-tocopherol.
Inject 20 μl of each calibration solution several times and determine the mean peak heights (areas). Using the mean peak heights (areas) plot a calibration graph.