OpenLegislation

Division 5.1.2.2 Preparation of solution for analysis

United Kingdom

Original text. Later amendments are not shown.

For the determination of copper, the solution prepared from point 5.1.1 can normally be used directly. If necessary to bring its concentration within the range of the calibration solutions, an aliquot portion may be pipetted into a 100 ml volumetric flask and made up to the mark with 0,5 mol/litre hydrochloric acid (3.3).

For the determination of iron, manganese and zinc, pipette an aliquot portion of the solution prepared from point 5.1.1 into a 100 ml volumetric flask, add 10 ml of lanthanum chloride solution (3.11) and make up to the mark with 0,5 mol/litre hydrochloric acid (3.3) (see also point 8 ‘Observation’).

Notes on Division 5

Footnotes

f1

Other methods of digestion may be used provided they have been demonstrated to have similar results (such as microwave pressure digestion).