  "url": "https://openlegislation.uk/eu-regulation-2009-152/annex-IV/division-E/division-3/division-3.9.3",
  "json_url": "https://openlegislation.uk/eu-regulation-2009-152/annex-IV/division-E/division-3/division-3.9.3.json",
  "legislation": "eur/2009/152",
  "legislation_title": "Commission Regulation (EC) No 152/2009 of 27 January 2009 laying down the methods of sampling and analysis for the official control of feed (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2009-152",
  "path": "annex/IV/division/E/division/3/division/3.9.3",
  "kind": "division",
  "number": "3.9.3",
  "heading": "Calibration solutions",
  "text": "Into a series of 50 ml calibrated flasks, transfer 5,0, 10,0, 15,0, 20,0 and 25,0 ml of the intermediate standard solution (3.9.2). Make up to the mark with mobile phase (3.8) and mix. These solutions correspond to 1,2, 2,4, 3,6, 4,8 and 6,0 μg/ml of robenidine respectively. These solutions must be freshly prepared before use.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2009/152/annex/IV/division/E/division/3/division/3.9.3",
    "retrieved_at": "2026-11-01T14:51:38.610873+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}