  "url": "https://openlegislation.uk/eu-regulation-2009-152/annex-V/division-B/chapter-II/division-6/division-6.5",
  "json_url": "https://openlegislation.uk/eu-regulation-2009-152/annex-V/division-B/chapter-II/division-6/division-6.5.json",
  "legislation": "eur/2009/152",
  "legislation_title": "Commission Regulation (EC) No 152/2009 of 27 January 2009 laying down the methods of sampling and analysis for the official control of feed (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2009-152",
  "path": "annex/V/division/B/chapter/II/division/6/division/6.5",
  "kind": "division",
  "number": "6.5",
  "heading": "Specific criteria for confirmatory methods",
  "text": "For GC-HRMS:\nIn HRMS, the resolution shall typically be greater than or equal to 10 000 for the entire mass range at 10 % valley.\nFulfilment of further identification and confirmation criteria as described in internationally recognised standards, for example, in standard EN 16215:2012 (Animal feed — Determination of dioxins and dioxin-like PCBs by GC-HRMS and of indicator PCBs by GC-HRMS) and/or in EPA methods 1613 and 1668 as revised.\nFor GC-MS/MS:\nMonitoring of at least 2 specific precursor ions, each with one specific corresponding transition product ion for all labelled and unlabelled analytes in the scope of analysis.\nMaximum permitted tolerance of relative ion intensities of ± 15 % for selected transition product ions in comparison to calculated or measured values (average from calibration standards), applying identical MS/MS conditions, in particular collision energy and collision gas pressure, for each transition of an analyte.\nResolution for each quadrupole to be set equal to or better than unit mass resolution (unit mass resolution: sufficient resolution to separate two peaks one mass unit apart) in order to minimise possible interferences on the analytes of interest.\nFulfilment of the further criteria as described in internationally recognised standards, for example, in standard EN 16215:2012 (Animal feed — Determination of dioxins and dioxin-like PCBs by GC-HRMS and of indicator PCBs by GC-HRMS) and/or in EPA methods 1613 and 1668 as revised, except the obligation to use GC-HRMS.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "F",
      "label": "F1",
      "text": "Substituted by Commission Regulation (EU) 2017/771 of 3 May 2017 amending Regulation (EC) No 152/2009 as regards the methods for the determination of the levels of dioxins and polychlorinated biphenyls (Text with EEA relevance)."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2009/152/annex/V/division/B/chapter/II/division/6/division/6.5",
    "retrieved_at": "2026-11-01T14:51:38.610873+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}