# Council Regulation (EC) No 428/2009 of 5 May 2009 setting up a Community regime for the control of exports, transfer, brokering and transit of dual-use items (Recast), Division [9A002]: ‘Marine gas turbine engines’ designed to use liquid fuel and having all of the following, and specially designed assemblies and components therefor:


a..Maximum continuous power when operating in "steady state mode" at standard reference conditions specified by ISO 3977-2:1997 (or national equivalent) of 24 245 kW or more; and
b..‘Corrected specific fuel consumption’ not exceeding 0,219 kg/kWh at 35 % of the maximum continuous power when using liquid fuel.
Note:
The term ‘marine gas turbine engines’ includes those industrial, or aero-derivative, gas turbine engines adapted for a ship’s electric power generation or propulsion.
Technical Note:
For the purposes of 9A002, ‘corrected specific fuel consumption’ is the specific fuel consumption of the engine corrected to a marine distillate liquid fuel having a net specific energy (i.e. net heating value) of 42MJ/kg (ISO 3977-2:1997).

---
Source: https://www.legislation.gov.uk/eur/2009/428/annex/I/division/11/division/1/division/9A002 (the official version)
Page: https://openlegislation.uk/eu-regulation-2009-428/annex-I/division-11/division-1/division-9A002