  "url": "https://openlegislation.uk/eu-regulation-2009-428/annex-I/division-4/division-2/division-2B206",
  "json_url": "https://openlegislation.uk/eu-regulation-2009-428/annex-I/division-4/division-2/division-2B206.json",
  "legislation": "eur/2009/428",
  "legislation_title": "Council Regulation (EC) No 428/2009 of 5 May 2009 setting up a Community regime for the control of exports, transfer, brokering and transit of dual-use items (Recast)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2009-428",
  "path": "annex/I/division/4/division/2/division/2B206",
  "kind": "division",
  "number": "[2B206]",
  "heading": "Dimensional inspection machines, instruments or systems, other than those specified in 2B006, as follows:",
  "text": "a..Computer controlled or numerically controlled coordinate measuring machines (CMM) having either of the following characteristics:\n1..Having only two axes and having a maximum permissible error of length measurement along any axis (one dimensional), identified as any combination of E0x,MPE, E0y,MPE, or E0z,MPE, equal to or less (better) than (1,25 + L/1 000) μm (where L is the measured length in mm) at any point within the operating range of the machine (i.e., within the length of the axis), according to ISO 10360-2:2009; or\n2..Three or more axes and having a three dimensional (volumetric) maximum permissible error of length measurement (E0,MPE) equal to or less (better) than (1,7 + L/800) μm (where L is the measured length in mm) at any point within the operating range of the machine (i.e., within the length of the axis), according to ISO 10360-2:2009;\nTechnical Note:\nThe E0,MPE of the most accurate configuration of the CMM specified according to ISO 10360-2:2009 by the manufacturer (e.g., best of the following: probe, stylus, length, motion parameters, environments) and with all compensations available shall be compared to the (1,7 + L/800) μm threshold.\nb..Systems for simultaneous linear-angular inspection of hemishells, having both of the following characteristics:\n1..\"Measurement uncertainty\" along any linear axis equal to or less (better) than 3,5 μm per 5 mm; and\n2..\"Angular position deviation\" equal to or less than 0,02o;\nc..‘Linear displacement’ measuring systems having all of the following characteristics:\nTechnical Note:\nFor the purpose of 2B206.c. ‘linear displacement’ means the change of distance between the measuring probe and the measured object.\n1..Containing a \"laser\"; and\n2..Capable of maintaining, for at least 12 hours, over a temperature range of ± 1 K (± 1 °C) around a standard temperature and standard pressure, all of the following:\na..A \"resolution\" over their full scale of 0,1 μm or better; and\nb..With a \"measurement uncertainty\" equal to or better (less) than (0,2 + L/2 000) μm (L is the measured length in mm).\nNote:\n2B206.c. does not control measuring interferometer systems, without closed or open loop feedback, containing a laser to measure slide movement errors of machine tools, dimensional inspection machines, or similar equipment.\nd..Linear variable differential transformer (LVDT) systems having both of the following characteristics:\nTechnical Note:\nFor the purpose of 2B206.d. ‘linear displacement’ means the change of distance between the measuring probe and the measured object.\n1..Having any of the following:\na..\"Linearity\" equal to or less (better) than 0,1 % measured from 0 to the full operating range, for LVDTs with an operating range up to 5 mm; or\nb..\"Linearity\" equal to or less (better) than 0,1 % measured from 0 to 5 mm for LVDTs with an operating range greater than 5 mm; and\n2..Drift equal to or better (less) than 0,1 % per day at a standard ambient test room temperature ± 1 K (± 1 °C).\nNote 1:\nMachine tools that can be used as measuring machines are controlled if they meet or exceed the criteria specified for the machine tool function or the measuring machine function.\nNote 2:\nA machine specified in 2B206 is controlled if it exceeds the control threshold anywhere within its operating range.\nTechnical Notes:\nAll parameters of measurement values in 2B206 represent plus/minus i.e., not total band.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "F",
      "label": "F1",
      "text": "Substituted by Commission Delegated Regulation (EU) 2020/1749 of 7 October 2020 amending Council Regulation (EC) No 428/2009 setting up a Community regime for the control of exports, transfer, brokering and transit of dual-use items."
    },
    {
      "type": "F",
      "label": "F2",
      "text": "Words in Annex 1 Entry 2B206.c.2 substituted (20.4.2022) by The Trade in Dual-Use Items (Council Regulation (EC) No 428/2009) (Amendment) Regulations 2022 (S.I. 2022/410), regs. 1, 2(2)(c)(i)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2009/428/annex/I/division/4/division/2/division/2B206",
    "retrieved_at": "2026-11-01T14:51:29.916257+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}