# Commission Regulation (EC) No 631/2009 of 22 July 2009 laying down detailed rules for the implementation of Annex I to Regulation (EC) No 78/2009 of the European Parliament and of the Council on the type-approval of motor vehicles with regard to the protection of pedestrians and other vulnerable road users, amending Directive 2007/46/EC and repealing Directives 2003/102/EC and 2005/66/EC, Division

Extent: E+W+S+N.I.

Accuracy of pedal force and disc temperature measurements shall be as follows:
Applicable as specified in point 7.2.5.
Measurement
Typical operating range of the transducers
Recommended maximum recording errors
Pedal force
0 to 2 000 N
±10 N
Brake disc temperature
0-1 000 °C
±5 °C
Brake Pressure
0-20 MPa
±100 kPa

---