Division 2.5 System requirements
United Kingdom
The data system shall have a resolution of 12 bits (± 0,05 %) or more and an accuracy of 2 LSB (± 0,1 %). Anti-aliasing filters shall be of order 4 or higher and the relevant data range fmax shall be 0 Hz to 30 Hz.
For fourth order filters the pass-band frequency fo (from 0 Hz to frequency fo) shall be greater than 2,37 × fmax if phase errors are subsequently adjusted in digital data processing, and greater than 5 × fmax otherwise. For fourth order filters the data sampling frequency fs shall be greater than 13,4 × fo.