  "legislation_title": "Commission Regulation (EC) No 761/2009 of 23 July 2009 amending, for the purpose of its adaptation to technical progress, Regulation (EC) No 440/2008 laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2009-761",
  "path": "annex/I/division/1/division/1.5/division/1.5.6/division/1.5.6.3",
  "kind": "division",
  "number": "1.5.6.3",
  "heading": "Procedure",
  "text": "The test substance is applied to the surface of a roughened glass plate as a homogeneous layer. In the case of solids, the plate is wetted uniformly by a solution of the substance in a suitable solvent and dried in an inert atmosphere. For the measurement, the coated plate is hung into the thermogravimetric analyser and subsequently its weight loss is measured continuously as a function of time.\nThe evaporation rate vT at a definite temperature is calculated from the weight loss Δm of the sample plate by\nv T = Δ m F · t (g cm –2 h –1 )\nwhere F is the surface area of the coated test substances, normally the surface area of the sample plate, and t is the time for weight loss Δm.\nThe vapour pressure pT is calculated on the basis of its function of evaporation rate vT:\nLog pT = C + D · log vT\nwhere C and D are constants specific for the experimental arrangement used, depending on the diameter of the measurement chamber and on the gas flow rate. These constants must be determined once by measuring a set of compounds with known vapour pressure and regressing log pT vs. log vT (11)(21)(22).\nThe relationship between the vapour pressure pT and the temperature T in Kelvin is given by\nLog pT = A + B · 1/T\nwhere A and B are constants obtained by regressing log pT vs. 1/T. With this equation, the vapour pressure can be calculated for any other temperature by extrapolation.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2009/761/annex/I/division/1/division/1.5/division/1.5.6/division/1.5.6.3",
    "retrieved_at": "2026-11-01T14:51:19.625001+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}