{
  "url": "https://openlegislation.uk/eu-regulation-2009-761/annex-I/division-1/division-1.5/division-1.5.7/division-1.5.7.2/division-2",
  "json_url": "https://openlegislation.uk/eu-regulation-2009-761/annex-I/division-1/division-1.5/division-1.5.7/division-1.5.7.2/division-2.json",
  "legislation": "eur/2009/761",
  "legislation_title": "Commission Regulation (EC) No 761/2009 of 23 July 2009 amending, for the purpose of its adaptation to technical progress, Regulation (EC) No 440/2008 laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2009-761",
  "path": "annex/I/division/1/division/1.5/division/1.5.7/division/1.5.7.2/division/2",
  "kind": "division",
  "number": null,
  "heading": null,
  "text": "In general, nitrogen is used as an inert carrier gas but, occasionally, another gas may be required (24). The carrier gas must be dry. The gas stream is split into 6 streams, controlled by needle valves (approximately 0,79 mm orifice), and flows into the box via 3,8 mm i.d. copper tubing. After temperature equilibration, the gas flows through the sample and the sorbent trap and exists from the box.\nSolid samples are loaded into 5 mm i.d. glass tubing between glass wool plugs (see Figure 9). Figure 10 shows a liquid sample holder and sorbent system. The most reproducible method for measuring the vapour pressure of liquids is to coat the liquid on glass beads or on an inert sorbent such as silica, and to pack the holder with these beads. As an alternative, the carrier gas may be made to pass a coarse frit and bubble through a column of the liquid test substance.\nFigure 9\nFigure 10\nThe sorbent system contains a front and a backup sorbent section. At very low vapour pressures, only small amounts are retained by the sorbent and the adsorption on the glass wool and the glass tubing between the sample and the sorbent may be a serious problem.\nTraps cooled with solid CO2 are another efficient way for collecting the vaporised material. They do not cause any back pressure on the saturator column and it is also easy to quantitatively remove the trapped material.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2009/761/annex/I/division/1/division/1.5/division/1.5.7/division/1.5.7.2/division/2",
    "retrieved_at": "2026-11-01T14:51:19.625001+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}