# Commission Regulation (EC) No 761/2009 of 23 July 2009 amending, for the purpose of its adaptation to technical progress, Regulation (EC) No 440/2008 laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) (Text with EEA relevance), Division 1.5.3.4.2: Length weighting of the fibre diameters

Extent: E+W+S+N.I.

Only those fibres that touch (or cross) an (infinitely) thin line drawn on the screen of the SEM are counted. For this reason a horizontal (or vertical) line is drawn across the centre of the screen.
Alternatively a single point is placed at the centre of the screen and a continuous scan in one direction across the filter is initiated. Each fibre of aspect ratio grater than 3:1 touching or crossing this point has its diameter measured and recorded.

---
Source: https://www.legislation.gov.uk/eur/2009/761/annex/II/division/1/division/1.5/division/1.5.3/division/1.5.3.4/division/1.5.3.4.2 (the official version)
Page: https://openlegislation.uk/eu-regulation-2009-761/annex-II/division-1/division-1.5/division-1.5.3/division-1.5.3.4/division-1.5.3.4.2
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.