  "legislation_title": "Commission Regulation (EC) No 761/2009 of 23 July 2009 amending, for the purpose of its adaptation to technical progress, Regulation (EC) No 440/2008 laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2009-761",
  "path": "annex/V/division/1/division/1.8/division/1.8.1",
  "kind": "division",
  "number": "1.8.1",
  "heading": "Equipment",
  "text": "The test may be conducted in conical or cylindrical flasks of appropriate capacity (e.g. 0,5 or 1,0 litre) closed with silicone or rubber stoppers, or in serum flasks with CO2-tight lids (e.g. with butyl rubber septa). Another option is to perform the test by use of multiple flasks and to harvest whole flasks, at least in duplicate, at each sample interval (see last paragraph in section 1.8.9.1). For non-volatile test substances that are not radiolabelled, gas-tight stoppers or lids are not required; loose cotton plugs that prevent contamination from air are suitable (see second paragraph in section 1.8.9.1). Slightly volatile substances should be tested in a biometer-type system with gentle stirring of the water surface. To be sure that no bacterial contamination occurs, optionally the vessels can be sterilised by heating or autoclaving prior to use. In addition, the following standard laboratory equipment is used:\nshaking table or magnetic stirrers for continuous agitation of the test flasks,\ncentrifuge,\npH meter,\nturbidimeter for nephelometric turbidity measurements,\noven or microwave oven for dry weight determinations,\nmembrane filtration apparatus,\nautoclave or oven for heat sterilisation of glassware,\nfacilities to handle 14C-labelled substances,\nequipment to quantify 14C-activity in samples from CO2-trapping solutions and, if required, from sediment samples,\nanalytical equipment for the determination of the test (and reference) substance if specific chemical analysis is used (e.g. gas chromatograph, high-pressure liquid chromatograph).",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2009/761/annex/V/division/1/division/1.8/division/1.8.1",
    "retrieved_at": "2026-11-01T14:51:19.625001+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}