# Regulation (EC) No 79/2009 of the European Parliament and of the Council of 14 January 2009 on type-approval of hydrogen-powered motor vehicles, and amending Directive 2007/46/EC (Text with EEA relevance), Division 5

Extent: E+W+S+N.I.

Internal leakage test: the purpose of the test is to provide evidence that the specified hydrogen components are free from internal leakage. In order to prove this, the hydrogen components are pressurised under different temperature conditions and observed for leakage. The hydrogen components must stay bubble free and must not leak internally at a higher rate than a specified number.

---
Source: https://www.legislation.gov.uk/eur/2009/79/annex/V/division/5 (the official version)