  "legislation_title": "Commission Regulation (EU) No 347/2010 of 21 April 2010 amending Commission Regulation (EC) No 245/2009 as regards the ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps (Text with EEA relevance)",
  "legislation_url": "https://openlegislation.uk/eu-regulation-2010-347",
  "path": "annex",
  "kind": "annex",
  "number": null,
  "heading": "Amendments in Annexes I, II, III and IV to Regulation (EC) No 245/2009",
  "text": "Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as follows:\n1.. Annex I is amended as follows:\n(a) the title is replaced by the following:\n‘Exemptions’;\n(b) the introductory sentence in point 1 is replaced by the following:\n‘The following lamps shall be exempt from the provisions of Annex III, provided that the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC states which of the technical parameters listed hereunder provide(s) a basis for their exemption:’;\n(c) points 1(c) and 1(d) are replaced by the following:\n(c) ‘blended high intensity discharge lamps having:\n6 % or more of total radiation of the range 250-780 nm in the range of 250-400 nm; and\n11 % or more of total radiation of the range 250-780 nm in the range of 630-780 nm; and\n5 % or more of total radiation of the range 250-780 nm in the range of 640-700 nm;\n(d) blended high intensity discharge lamps having:\nthe peak of the radiation between 315-400 nm (UVA) or 280-315 nm (UVB);’;\n(d) point 2 is replaced by the following:\n‘2.\nThe following products shall be exempt from the provisions of Annex III, provided that in all forms of product information it is stated that they are not intended for general lighting use within the meaning of this Regulation, or that they are intended for use in applications listed in points (b) to (e):\n(a) products intended for use in applications other than general lighting and products incorporated into products which do not provide a general lighting function;\n(b) lamps covered by the requirements of Directives 94/9/EC of the European Parliament and of the Council or Directive 1999/92/EC of the European Parliament and of the Council;\n(c) emergency lighting luminaires and emergency sign luminaires within the meaning of Directive 2006/95/EC of the European Parliament and of the Council.\n(d) ballasts intended for use in luminaires defined in paragraph (c) and designed to operate lamps in emergency conditions;\n(e) luminaires covered by the requirements of Directive 94/9/EC, Directive 1999/92/EC, Directive 2006/42/EC of the European Parliament and of the Council, Council Directive 93/42/EEC, Council Directive 88/378/EEC and luminaires integrated into equipment covered by these requirements.\nThe intended purpose shall be stated for each product in the product information, and the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC shall list the technical parameters that make the product design specific for the stated intended purpose.’\n2.. Annex II is amended as follows:\n(a) the first sentence is deleted;\n(b) The following sentence is added to point 1(c):\n‘For the purposes of Table 6 in Annex III, the LSF shall be measured in high frequency operating mode with a switching cycle of 11h/1h.’\n(c) The following point (o) is added to point 3:\n(o) ‘“Blended lamp” means a lamp containing a mercury vapour lamp and an incandescent lamp filament connected in series in the same bulb.’\n3.. Annex III is amended as follows:\n(a) The following paragraph is added before Table 1:\n‘Spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) shall comply with the requirements set out in Table 5 for T9 circular lamps.’\n(b) Table 2 is replaced by the following:\n‘\nTable 2\nRated minimum efficacy values for single capped fluorescent lamps working on electromagnetic and electronic ballast\nSmall single parallel tube, lamp cap G23 (2 pin) or 2G7 (4 pin)\nDouble parallel tubes, lamp cap G24d (2 pin) or G24q (4 pin)\nTriple parallel tubes, lamp cap GX24d (2 pin) or GX24q (4 pin)\nNominal wattage(W)\nRated luminous efficacy (lm/W), 100 h initial value\nNominal wattage(W)\nRated luminous efficacy (lm/W), 100 h initial value\nNominal wattage(W)\nRated luminous efficacy (lm/W), 100 h initial value\n5\n48\n10\n60\n13\n62\n7\n57\n13\n69\n18\n67\n9\n67\n18\n67\n26\n66\n11\n76\n26\n66\n4 legs in one plane, lamp cap 2G10(4 pin)\nLong single parallel tube, lamp cap 2G11(4 pin)\nNominal wattage(W)\nRated luminous efficacy (lm/W), 100 h initial value\nNominal wattage(W)\nRated luminous efficacy (lm/W), 100 h initial value\n18\n61\n18\n67\n24\n71\n24\n75\n36\n78\n34\n82\n36\n81\n’\n(c) Table 3 is replaced by the following:\n‘\nTable 3\nRated minimum efficacy values for single capped fluorescent lamps, working only on electronic ballast\nTriple parallel tubes, lamp cap GX24q(4 pin)\nFour parallel tubes, lamp cap GX24q(4 pin)\nLong single parallel tube, lamp cap 2G11(4 pin)\nNominal wattage(W)\nRated luminous efficacy (lm/W), 100 h initial value\nNominal wattage(W)\nRated luminous efficacy (lm/W), 100 h initial value\nNominal wattage(W)\nRated luminous efficacy (lm/W), 100 h initial value\n32\n75\n57\n75\n40\n83\n42\n74\n70\n74\n55\n82\n57\n75\n80\n75\n70\n74\n’\n(d) Table 6 is replaced by the following:\n‘\nTable 6\nDeduction percentages for rated minimum efficacy values for fluorescent lamps with high colour temperature and/or high colour rendering and/or second lamp envelope and/or long life\nLamp parameter\nDeduction from luminous efficacy at 25 °C\nTc ≥ 5 000 K\n-10 %\n95 ≥ Ra > 90\n-20 %\nRa > 95\n-30 %\nSecond lamp envelope\n-10 %\nLamp Survival Factor ≥ 0,50 after 40 000 burning hours\n-5 %\n’\n(e) In Annex III.1.1.B, the sentence\n‘The corrections defined for the first stage (Table 6) shall continue to apply’\nis replaced by\n‘The corrections (Table 6) and the specific requirements for spiral-shaped double capped fluorescent lamps defined for the first stage shall continue to apply.’;\n(f) The title of Table 7 is replaced by the following:\n‘ Table 7\nRated minimum efficacy values for high pressure sodium lamps with Ra ≤ 60 ’;\n(g) The title of Table 8 is replaced by the following:\n‘ Table 8\nRated minimum efficacy values for Metal Halide Lamps with Ra ≤ 80 and for high pressure sodium lamps with Ra > 60 ’\n(h) The second paragraph of Annex III.1.1.C is replaced by the following:\n‘Fluorescent lamps without integrated ballast shall be able to operate with ballasts of energy efficiency class A2 or more efficient ballasts in accordance with point 2.2 of Annex III. In addition they may also operate with ballasts of less efficient classes than A2.’\n(i) Table 11 is replaced by the following:\n‘\nTable 11\nLamp lumen maintenance factors for single and double capped fluorescent lamps — Stage 2\nLamp lumen maintenance factor\nBurning hours\nLamp types\n2 000\n4 000\n8 000\n16 000\nDouble-Capped Fluorescent lamps operating on non-high frequency ballasts\n0,95\n0,92\n0,9\n—\nT8 Double-Capped Fluorescent lamps on high frequency ballast with warmstart\n0,96\n0,92\n0,91\n0,9\nOther Double-Capped Fluorescent lamps on high frequency ballast with warmstart\n0,95\n0,92\n0,9\n0,9\nCircular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5)\n0,8\n0,74\n—\n—\n0,72 at 5 000 burning hours\nCircular Single-Capped Fluorescent lamps operating on high frequency ballasts\n0,85\n0,83\n0,8\n—\n0,75 at 12 000 burning hours\nOther Single-Capped Fluorescent lamps operating on non-high frequency ballasts\n0,85\n0,78\n0,75\n—\nOther Single-Capped Fluorescent lamps on high frequency ballast with warmstart\n0,9\n0,84\n0,81\n0,78\n’\n(j) The following introductory phrase and Table 11a is added after Table 11:\n‘The following cumulative deductions shall be applied to the values in Table 11:\nTable 11a\nDeduction percentages for fluorescent lamp lumen maintenance requirements\nLamp parameter\nDeduction from lamp lumen maintenance requirement\nLamps with 95 ≥ Ra > 90\nAt burning hours ≤ 8 000 h: – 5 %\nAt burning hours > 8 000 h: – 10 %\nLamps with Ra > 95\nAt burning hours ≤ 4 000 h: – 10 %\nAt burning hours > 4 000 h: – 15 %\nLamps with a colour temperature ≥ 5 000 K\n-10 %\n’\n(k) Table 12 is replaced by the following:\n‘\nTable 12\nLamp survival factors for single and double capped fluorescent lamps — Stage 2\nLamp survival factor\nBurning hours\nLamp types\n2 000\n4 000\n8 000\n16 000\nDouble-Capped Fluorescent lamps operating on non-high frequency ballasts\n0,99\n0,97\n0,9\n—\nDouble-Capped Fluorescent lamps on high frequency ballast with warmstart\n0,99\n0,97\n0,92\n0,9\nCircular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5)\n0,98\n0,77\n—\n—\n0,50 at 5 000 burning hours\nCircular Single-Capped Fluorescent lamps operating on high frequency ballasts\n0,99\n0,97\n0,85\n—\n0,50 at 12 000 burning hours\nOther Single-Capped Fluorescent lamps operating on non-high frequency ballasts\n0,98\n0,9\n0,5\n—\nOther Single-Capped Fluorescent lamps on high frequency ballast with warmstart\n0,99\n0,98\n0,88\n—\n’\n(l) Table 13 is replaced by the following:\n‘\nTable 13\nLamp lumen maintenance factors and lamp survival factors for high pressure sodium lamps — Stage 2\nHigh pressure sodium lamp category and burning hours for measurement\nLamp lumen maintenance factor\nLamp survival factor\nP ≤ 75 W\nLLMF and LSF measured at 12 000 burning hours\nRa ≤ 60\n> 0,80\n> 0,90\nRa > 60\n> 0,75\n> 0,75\nall retrofit lamps designed to operate on high pressure mercury vapour lamp ballast\n> 0,75\n> 0,80\nP > 75 W\nLLMF and LSF measured at 16 000 burning hours\nRa ≤ 60\n> 0,85\n> 0,90\nRa > 60\n> 0,70\n> 0,65\nall retrofit lamps designed to operate on high pressure mercury vapour lamp ballast\n> 0,75\n> 0,55\nThe requirements in Table 13 for retrofit lamps designed to operate on high pressure mercury vapour lamp ballast shall be applicable until 6 years after the entry into force of this Regulation.’;\n(m) Annex III.1.3(i) is replaced by the following:\n(i) ‘Ambient temperature inside the luminaire at which the lamp was designed to maximise its luminous flux. If this temperature is equal to or lower than 0 °C or equal to or higher than 50 °C, it shall be stated that the lamp is not suitable for indoor use at standard room temperatures.’;\n(n) The following point (j) is added to point 1.3 of Annex III:\n(j) ‘For fluorescent lamps without integrated ballast, the energy efficiency index(es) of ballasts as defined in Table 17 with which the lamp can operate.’;\n(o) Table 17 is replaced by the following:\n‘\nTable 17\nEnergy efficiency index requirements for non-dimmable ballasts for fluorescent lamps\nLAMP DATA\nBALLAST EFFICIENCY (Plamp/Pinput)\nNon-dimmable\nLamp type\nNominal Wattage\nILCOS CODE\nRated/typical wattage\nA2 BAT\nA2\nA3\nB1\nB2\n50 Hz\nHF\nW\nW\nW\nT8\n15\nFD-15-E-G13-26/450\n15\n13,5\n87,8 %\n84,4 %\n75,0 %\n67,9 %\n62,0 %\nT8\n18\nFD-18-E-G13-26/600\n18\n16\n87,7 %\n84,2 %\n76,2 %\n71,3 %\n65,8 %\nT8\n30\nFD-30-E-G13-26/900\n30\n24\n82,1 %\n77,4 %\n72,7 %\n79,2 %\n75,0 %\nT8\n36\nFD-36-E-G13-26/1200\n36\n32\n91,4 %\n88,9 %\n84,2 %\n83,4 %\n79,5 %\nT8\n38\nFD-38-E-G13-26/1050\n38,5\n32\n87,7 %\n84,2 %\n80,0 %\n84,1 %\n80,4 %\nT8\n58\nFD-58-E-G13-26/1500\n58\n50\n93,0 %\n90,9 %\n84,7 %\n86,1 %\n82,2 %\nT8\n70\nFD-70-E-G13-26/1800\n69,5\n60\n90,9 %\n88,2 %\n83,3 %\n86,3 %\n83,1 %\nTC-L\n18\nFSD-18-E-2G11\n18\n16\n87,7 %\n84,2 %\n76,2 %\n71,3 %\n65,8 %\nTC-L\n24\nFSD-24-E-2G11\n24\n22\n90,7 %\n88,0 %\n81,5 %\n76,0 %\n71,3 %\nTC-L\n36\nFSD-36-E-2G11\n36\n32\n91,4 %\n88,9 %\n84,2 %\n83,4 %\n79,5 %\nTCF\n18\nFSS-18-E-2G10\n18\n16\n87,7 %\n84,2 %\n76,2 %\n71,3 %\n65,8 %\nTCF\n24\nFSS-24-E-2G10\n24\n22\n90,7 %\n88,0 %\n81,5 %\n76,0 %\n71,3 %\nTCF\n36\nFSS-36-E-2G10\n36\n32\n91,4 %\n88,9 %\n84,2 %\n83,4 %\n79,5 %\nTC-D / DE\n10\nFSQ-10-E-G24q=1\nFSQ-10-I-G24d=1\n10\n9,5\n89,4 %\n86,4 %\n73,1 %\n67,9 %\n59,4 %\nTC-D / DE\n13\nFSQ-13-E-G24q=1\nFSQ-13-I-G24d=1\n13\n12,5\n91,7 %\n89,3 %\n78,1 %\n72,6 %\n65,0 %\nTC-D / DE\n18\nFSQ-18-E-G24q=2\nFSQ-18-I-G24d=2\n18\n16,5\n89,8 %\n86,8 %\n78,6 %\n71,3 %\n65,8 %\nTC-D / DE\n26\nFSQ-26-E-G24q=3\nFSQ-26-I-G24d=3\n26\n24\n91,4 %\n88,9 %\n82,8 %\n77,2 %\n72,6 %\nTC-T / TE\n13\nFSM-13-E-GX24q=1\nFSM-13-I-GX24d=1\n13\n12,5\n91,7 %\n89,3 %\n78,1 %\n72,6 %\n65,0 %\nTC-T / TE\n18\nFSM-18-E-GX24q=2\nFSM-18-I-GX24d=2\n18\n16,5\n89,8 %\n86,8 %\n78,6 %\n71,3 %\n65,8 %\nTC-T / TC-TE\n26\nFSM-26-E-GX24q=3\nFSM-26-I-GX24d=3\n26,5\n24\n91,4 %\n88,9 %\n82,8 %\n77,5 %\n73,0 %\nTC-DD / DDE\n10\nFSS-10-E-GR10q\nFSS-10-L/P/H-GR10q\n10,5\n9,5\n86,4 %\n82,6 %\n70,4 %\n68,8 %\n60,5 %\nTC-DD / DDE\n16\nFSS-16-E-GR10q\nFSS-16-I-GR8\nFSS-16-L/P/H-GR10q\n16\n15\n87,0 %\n83,3 %\n75,0 %\n72,4 %\n66,1 %\nTC-DD / DDE\n21\nFSS-21-E-GR10q\nFSS-21-L/P/H-GR10q\n21\n19,5\n89,7 %\n86,7 %\n78,0 %\n73,9 %\n68,8 %\nTC-DD / DDE\n28\nFSS-28-E-GR10q\nFSS-28-I-GR8\nFSS-28-L/P/H-GR10q\n28\n24,5\n89,1 %\n86,0 %\n80,3 %\n78,2 %\n73,9 %\nTC-DD / DDE\n38\nFSS-38-E-GR10q\nFSS-38-L/P/H-GR10q\n38,5\n34,5\n92,0 %\n89,6 %\n85,2 %\n84,1 %\n80,4 %\nTC\n5\nFSD-5-I-G23\nFSD-5-E-2G7\n5,4\n5\n72,7 %\n66,7 %\n58,8 %\n49,3 %\n41,4 %\nTC\n7\nFSD-7-I-G23\nFSD-7-E-2G7\n7,1\n6,5\n77,6 %\n72,2 %\n65,0 %\n55,7 %\n47,8 %\nTC\n9\nFSD-9-I-G23\nFSD-9-E-2G7\n8,7\n8\n78,0 %\n72,7 %\n66,7 %\n60,3 %\n52,6 %\nTC\n11\nFSD-11-I-G23\nFSD-11-E-2G7\n11,8\n11\n83,0 %\n78,6 %\n73,3 %\n66,7 %\n59,6 %\nT5\n4\nFD-4-E-G5-16/150\n4,5\n3,6\n64,9 %\n58,1 %\n50,0 %\n45,0 %\n37,2 %\nT5\n6\nFD-6-E-G5-16/225\n6\n5,4\n71,3 %\n65,1 %\n58,1 %\n51,8 %\n43,8 %\nT5\n8\nFD-8-E-G5-16/300\n7,1\n7,5\n69,9 %\n63,6 %\n58,6 %\n48,9 %\n42,7 %\nT5\n13\nFD-13-E-G5-16/525\n13\n12,8\n84,2 %\n80,0 %\n75,3 %\n72,6 %\n65,0 %\nT9-C\n22\nFSC-22-E-G10q-29/200\n22\n19\n89,4 %\n86,4 %\n79,2 %\n74,6 %\n69,7 %\nT9-C\n32\nFSC-32-E-G10q-29/300\n32\n30\n88,9 %\n85,7 %\n81,1 %\n80,0 %\n76,0 %\nT9-C\n40\nFSC-40-E-G10q-29/400\n40\n32\n89,5 %\n86,5 %\n82,1 %\n82,6 %\n79,2 %\nT2\n6\nFDH-6-L/P-W4,3x8,5d-7/220\n5\n72,7 %\n66,7 %\n58,8 %\nT2\n8\nFDH-8-L/P-W4,3x8,5d-7/320\n7,8\n76,5 %\n70,9 %\n65,0 %\nT2\n11\nFDH-11-L/P-W4,3x8,5d-7/420\n10,8\n81,8 %\n77,1 %\n72,0 %\nT2\n13\nFDH-13-L/P-W4,3x8,5d-7/520\n13,3\n84,7 %\n80,6 %\n76,0 %\nT2\n21\nFDH-21-L/P-W4,3x8,5d-7/\n21\n88,9 %\n85,7 %\n79,2 %\nT2\n23\nFDH-23-L/P-W4,3x8,5d-7/\n23\n89,8 %\n86,8 %\n80,7 %\nT5-E\n14\nFDH-14-G5-L/P-16/550\n13,7\n84,7 %\n80,6 %\n72,1 %\nT5-E\n21\nFDH-21-G5-L/P-16/850\n20,7\n89,3 %\n86,3 %\n79,6 %\nT5-E\n24\nFDH-24-G5-L/P-16/550\n22,5\n89,6 %\n86,5 %\n80,4 %\nT5-E\n28\nFDH-28-G5-L/P-16/1150\n27,8\n89,8 %\n86,9 %\n81,8 %\nT5-E\n35\nFDH-35-G5-L/P-16/1450\n34,7\n91,5 %\n89,0 %\n82,6 %\nT5-E\n39\nFDH-39-G5-L/P-16/850\n38\n91,0 %\n88,4 %\n82,6 %\nT5-E\n49\nFDH-49-G5-L/P-16/1450\n49,3\n91,6 %\n89,2 %\n84,6 %\nT5-E\n54\nFDH-54-G5-L/P-16/1150\n53,8\n92,0 %\n89,7 %\n85,4 %\nT5-E\n80\nFDH-80-G5-L/P-16/1150\n80\n93,0 %\n90,9 %\n87,0 %\nT5-E\n95\nFDH-95-G5-L/P-16/1150\n95\n92,7 %\n90,5 %\n84,1 %\nT5-E\n120\nFDH-120-G5-L/P-16/1450\n120\n92,5 %\n90,2 %\n84,5 %\nT5-C\n22\nFSCH-22-L/P-2GX13-16/225\n22,3\n88,1 %\n84,8 %\n78,8 %\nT5-C\n40\nFSCH-40-L/P-2GX13-16/300\n39,9\n91,4 %\n88,9 %\n83,3 %\nT5-C\n55\nFSCH-55-L/P-2GX13-16/300\n55\n92,4 %\n90,2 %\n84,6 %\nT5-C\n60\nFSCH-60-L/P-2GX13-16/375\n60\n93,0 %\n90,9 %\n85,7 %\nTC-LE\n40\nFSDH-40-L/P-2G11\n40\n91,4 %\n88,9 %\n83,3 %\nTC-LE\n55\nFSDH-55-L/P-2G11\n55\n92,4 %\n90,2 %\n84,6 %\nTC-LE\n80\nFSDH-80-L/P-2G11\n80\n93,0 %\n90,9 %\n87,0 %\nTC-TE\n32\nFSMH-32-L/P-2GX24q=3\n32\n91,4 %\n88,9 %\n82,1 %\nTC-TE\n42\nFSMH-42-L/P-2GX24q=4\n43\n93,5 %\n91,5 %\n86,0 %\nTC-TE\n57\nFSM6H-57-L/P-2GX24q=5\nFSM8H-57-L/P-2GX24q=5\n56\n91,4 %\n88,9 %\n83,6 %\nTC-TE\n70\nFSM6H-70-L/P-2GX24q=6\nFSM8H-70-L/P-2GX24q=6\n70\n93,0 %\n90,9 %\n85,4 %\nTC-TE\n60\nFSM6H-60-L/P-2G8=1\n63\n92,3 %\n90,0 %\n84,0 %\nTC-TE\n62\nFSM8H-62-L/P-2G8=2\n62\n92,2 %\n89,9 %\n83,8 %\nTC-TE\n82\nFSM8H-82-L/P-2G8=2\n82\n92,4 %\n90,1 %\n83,7 %\nTC-TE\n85\nFSM6H-85-L/P-2G8=1\n87\n92,8 %\n90,6 %\n84,5 %\nTC-TE\n120\nFSM6H-120-L/P-2G8=1\nFSM8H-120-L/P-2G8=1\n122\n92,6 %\n90,4 %\n84,7 %\nTC-DD\n55\nFSSH-55-L/P-GRY10q3\n55\n92,4 %\n90,2 %\n84,6 %\n’\n4.. The following paragraph is added after the first paragraph of Annex IV:\n‘Member States authorities shall use reliable, accurate and reproducible measurement procedures, which take into account the generally recognised state of the art measurement methods, including methods set out in documents the reference numbers of which have been published for that purpose in the Official Journal of the European Union.’",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "OJ L 100, 19.4.1994, p. 1."
    },
    {
      "type": "footnote",
      "label": "f2",
      "text": "OJ L 23, 28.1.2000, p. 57."
    },
    {
      "type": "footnote",
      "label": "f3",
      "text": "OJ L 374, 27.12.2006, p. 10."
    },
    {
      "type": "footnote",
      "label": "f4",
      "text": "OJ L 157, 9.6.2006, p. 24."
    },
    {
      "type": "footnote",
      "label": "f5",
      "text": "OJ L 169, 12.7.1993, p. 1."
    },
    {
      "type": "footnote",
      "label": "f6",
      "text": "OL L 187, 16.7.1988, p. 1.’"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2010/347/annex",
    "retrieved_at": "2026-11-01T14:50:50.553701+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",