# Commission Regulation (EU) No 406/2010 of 26 April 2010 implementing Regulation (EC) No 79/2009 of the European Parliament and of the Council on type-approval of hydrogen-powered motor vehicles (Text with EEA relevance), Division 6.3.7.1.1


The burst pressure shall be at least equal to the burst pressure used for the mechanical calculations. For steel tanks that is:
(a)either the Maximum Allowable Working Pressure (MAWP) (in MPa) plus 0,1 MPa multiplied by 3,25;
(b)or the Maximum Allowable Working Pressure (MAWP) (in MPa) plus 0,1 MPa multiplied by 1,5 and multiplied by Rm/Rp, where Rm means minimum ultimate tensile strength and Rp means minimum yield strength.

---
Source: https://www.legislation.gov.uk/eur/2010/406/annex/III/part/2/division/6/division/6.3/division/6.3.7/division/6.3.7.1/division/6.3.7.1.1 (the official version)