# Commission Regulation (EU) No 406/2010 of 26 April 2010 implementing Regulation (EC) No 79/2009 of the European Parliament and of the Council on type-approval of hydrogen-powered motor vehicles (Text with EEA relevance), Division 6.3.8.2.3.4


Once the safety device opens, the test shall continue until the blow off of the safety device has finished. During the test the tank shall not burst and the pressure inside the inner tank shall not exceed the permissible fault range of the inner tank. In the case of steel inner tanks, the tank pressure shall not exceed 136 per cent of the Maximum Allowable Working Pressure (MAWP) of the inner tank. For other materials, an equivalent level of safety shall be applied.

---