# Commission Regulation (EU) No 406/2010 of 26 April 2010 implementing Regulation (EC) No 79/2009 of the European Parliament and of the Council on type-approval of hydrogen-powered motor vehicles (Text with EEA relevance), Division 3.1.1.1


The primary pressure relief device for the inner tank shall limit the pressure inside the tank to not more than 110 per cent of the Maximum Allowable Working Pressure (MAWP), even in case of a sudden vacuum loss. This device shall be a safety valve or equivalent and shall be connected directly to the gaseous part under normal operating conditions.

---