# Commission Regulation (EU) No 406/2010 of 26 April 2010 implementing Regulation (EC) No 79/2009 of the European Parliament and of the Council on type-approval of hydrogen-powered motor vehicles (Text with EEA relevance), Division 4.2.2


The pressure supply system shall be equipped with a positive shut-off valve and a pressure gauge, having a pressure range of not less than 1,5 times nor more than 2 times the test pressure and the accuracy of the gauge shall be 1 per cent of the pressure range.

---