  "heading": null,
  "text": "The drop tests shall be performed at ambient temperature without internal pressurisation or attached valves. A plug may be inserted in the threaded ports to prevent damage to the threads and seal surfaces.\nThe surface onto which the container is dropped shall be a smooth, horizontal concrete pad or similar rigid floor.\nThe container shall be tested in the following sequence:\n(a)Drop once from a horizontal position with the bottom 1,8 m above the ground;\n(b)Drop once onto each end of the container from a vertical position with a potential energy ≥ 488 J, but in no case shall the bottom end be more than 1,8 m above the ground;\n(c)Drop once at a 45° angle, and then for non-symmetrical or non-cylindrical containers rotate the container through 90° along its longitudinal axis and drop again at a 45° angle, with its centre of gravity 1,8 m above the ground. However, if the bottom is closer to the ground than 0,6 m, the drop angle shall be changed to maintain a minimum height of 0,6 m and the centre of gravity 1,8 m above the ground;\n(d)No attempt shall be made to prevent bouncing of the container, but it may be prevented from falling over during the vertical drop test;\n(e)Pressure cycle the container between ≤ 2,0 MPa and ≥ 1,25 times nominal working pressure for three times the number of filling cycles calculated in accordance with section 2.7.6.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eur/2010/406/annex/IV/part/2/division/4/division/4.2/division/4.2.10/division/4.2.10.2/division/4.2.10.2.1",
    "retrieved_at": "2026-11-01T14:50:48.674921+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}