# Commission Regulation (EU) No 406/2010 of 26 April 2010 implementing Regulation (EC) No 79/2009 of the European Parliament and of the Council on type-approval of hydrogen-powered motor vehicles (Text with EEA relevance), Division 4.2.9.3: Requirement


The containers shall be cycle tested without showing evidence of rupture, leakage, or fibre unravelling.
If leak test is required, the leak test requirements shall be met.
The containers shall not burst at less than 85 per cent of the nominal working pressure times the burst pressure ratio given in section 3.6.

---
Source: https://www.legislation.gov.uk/eur/2010/406/annex/IV/part/2/division/4/division/4.2/division/4.2.9/division/4.2.9.3 (the official version)
Page: https://openlegislation.uk/eu-regulation-2010-406/annex-IV/part-2/division-4/division-4.2/division-4.2.9/division-4.2.9.3
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.