Pressure relief devices shall be subjected to 1,5 times the number of filling cycles calculated in accordance with section 2.7.6. at both the minimum and maximum material temperatures in accordance with section 2.7.5.1.
The pressure shall periodically change from 2 MPa to 1,25 times nominal working pressure at a rate not exceeding 6 cycles per minute, except when tested at the minimum material temperature when the maximum test pressure shall be nominal working pressure.
If fusible metal is used in a pressure relief device it shall show no additional visible sign of extrusion beyond the initial settling.

---