OpenLegislation

Division 2.1.5.1

United Kingdom

Original text. Later amendments are not shown.

The spray nozzle, adjusted to full fan pattern and maximum flow, shall be held perpendicular to and at a distance of between 200 and 250 mm from the glazed surface, and so directed as to form an even layer of ice right across the windscreen from one side to the other.

  1. 2.1.5.1.1Division 2.1.5.1.1