Division I.7.2 Procedure
United Kingdom
Take from the pre-treated laboratory test sample a test specimen weighing at least 1 g. Cut yarn or cloth into lengths of about 10 mm, dissected as much as possible. Dry the specimen in a weighing bottle, cool it in the desiccator and weigh it. Transfer the specimen to the glass vessel specified in the appropriate section of the relevant F1... method, reweigh the weighing bottle immediately and obtain the dry mass of the specimen by difference. Complete the test as specified in the appropriate section of the applicable method. Examine the residue microscopically to check that the treatment has in fact completely removed the soluble fibre.
Annotations
Textual amendments
- F1
Word in Annex 8 Ch. 2 para. 1.7.2 omitted (31.12.2020) by virtue of The Textile Products (Amendment) (EU Exit) Regulations 2018 (S.I. 2018/1398), regs. 1, 3(16)(a); 2020 c. 1, Sch. 5 para. 1(1)