# Commission Regulation (EU) No 142/2011 of 25 February 2011 implementing Regulation (EC) No 1069/2009 of the European Parliament and of the Council laying down health rules as regards animal by-products and derived products not intended for human consumption and implementing Council Directive 97/78/EC as regards certain samples and items exempt from veterinary checks at the border under that Directive (Text with EEA relevance), Division Section 2: Operating conditions

Extent: E+W+S+N.I.

Incineration or co-incineration plants shall be designed, equipped, built and operated in such a way that the gas resulting from the process is raised in a controlled and homogeneous fashion, even under the most unfavourable conditions, to a temperature of 850 °C for at least 2 seconds or to a temperature of 1 100 °C for 0.2 seconds, as measured near the inner wall or at another representative point of the chamber where the incineration or the co-incineration is carried out, as authorised by the competent authority.

---
Source: https://www.legislation.gov.uk/eur/2011/142/annex/III/chapter/I/section/2 (the official version)
Page: https://openlegislation.uk/eu-regulation-2011-142/annex-III/chapter-I/section-2
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.