Division (d) The manure must be mixed with quick lime (CaO) which has a medium to high reactivity of less than six minutes to achieve a 40 °C rise in temperature as per the criteria in the reactivity test 5.10 in the CEN EN 459-2:2002 method .F1
United Kingdom
The mixing must be carried out with two mixers which are operating in line, with two screws per mixer.
Both mixers must:
- (i)
have a screw diameter of 0,55 m and a screw length of 3,5 m;
- (ii)
operate with a power of 30 kW and a rotation speed of the screw of 156 rpm;
- (iii)
have a treatment capacity of 10 tonnes per hour.
The mean blending duration must be approximately two minutes.
Annotations
Textual amendments
Footnotes
- f1
-
CEN EN 459-2:2002 method CEN/TC 51 - Cement and building limes. European Committee for Standardisation,