Division 2 The following information shall be displayed:
United Kingdom
- (1)
overall efficiency (η), rounded to 1 decimal place;
- (2)
measurement category used to determine the energy efficiency (A-D);
- (3)
efficiency category (static or total);
- (4)
efficiency grade at optimum energy efficiency point;
- (5)
whether the calculation of fan efficiency assumed use of a VSD and if so, whether the VSD is integrated within the fan or the VSD must be installed with the fan;
- (6)
year of manufacture;
- (7)
manufacturer’s name or trade mark, commercial registration number and place of manufacturer;
- (8)
product’s model number;
- (9)
the rated motor power input(s) (kW), flow rate(s) and pressure(s) at optimum energy efficiency;
- (10)
rotations per minute at the optimum energy efficiency point;
- (11)
the ‘specific ratio’;
- (12)
information relevant for facilitating disassembly, recycling or disposal at end-of-life;
- (13)
information relevant to minimise impact on the environment and ensure optimal life expectancy as regards installation, use and maintenance of the fan;
- (14)
description of additional items used when determining the fan energy efficiency, such as ducts, that are not described in the measurement category and not supplied with the fan.