Division (a) The following information shall be included in the label:

United Kingdom

Original text. Later amendments are not shown.

  1. I..

    supplier’s name or trade mark;

  2. II..

    supplier’s model identifier;

  3. III..

    text ‘SEER’ and ‘SCOP’ for cooling and heating, with a blue fan and air wave indication for SEER and red fan and air wave indication for SCOP;

  4. IV..

    the energy efficiency; the head of the arrow containing the energy efficiency class of the appliance shall be placed at the same height as the head of the arrow of the relevant energy efficiency class. Energy efficiency must be indicated for cooling and heating. For heating, energy efficiency for Average heating season is mandatory. Indication of efficiency for Warmer and Colder seasons is optional;

  5. V..

    for cooling mode: design load in kW, rounded up to one decimal;

  6. VI..

    for heating mode: design load in kW, for up to 3 heating seasons rounded up to one decimal. Values for heating seasons for which the design load is not provided shall be indicated as ‘X’;

  7. VII..

    for cooling mode: seasonal energy efficiency ratio (SEER value), rounded up to one decimal;

  8. VIII..

    for heating mode: seasonal coefficient of performance (SCOP value), for up to 3 heating seasons rounded up to one decimal. Values for heating seasons for which SCOP is not provided shall be indicated as ‘X’;

  9. IX..

    annual energy consumption in kWh per year, for cooling and heating, rounded up to the nearest integer. Values for climate profiles for which annual energy consumption is not provided shall be indicated as ‘X’;

  10. X..

    sound power levels for indoor and outdoor units expressed in dB(A) re1 pW, rounded to the nearest integer;

  11. XI.

    European map with a display of three indicative heating seasons and corresponding colour squares.

    All the requested values shall be determined in accordance with Annex VII.