For gas-fired household tumble driers, the energy consumption on gas for the standard cotton programme at full and partial load for the information in Annex II, III and IV is calculated in kWhGas and rounded to two decimal places, as:

AE C(Gas) = 160 × (3 × Egdry  + 4 × Egdry1/2 )/7

For gas-fired household tumble driers, the energy consumption on electricity for the standard cotton programme at full and partial load for the information in Annex II, III and IV is calculated in kWh and rounded to two decimal places, as:

AEC(Gas)el = 160 × (3 × Egdry,a + 4 × Egdry1/2,a )/7 + ((Pl × Tl × 160) + Po × [525 600 – (Tt × 160) – (Tl × 160)])/60 × 1 000