OpenLegislation

Division B.2 Method B

United Kingdom

Original text. Later amendments are not shown.

Each operator shall determine emissions considering all processes relevant to emissions at the installation as well as the amount of CO2 captured and transferred to the transport facility using the following formula:

Emissions [t CO2] = CO2 fugitive + CO2 vented + CO2 leakage events + CO2 installations

Where:

Emissions
  • Total CO2 emissions of the transport network [t CO2];

  • CO2 fugitive
  • Amount of fugitive emissions [t CO2] from CO2 transported in the transport network, including from seals, valves, intermediate compressor stations and intermediate storage facilities;

  • CO2 vented
  • Amount of vented emissions [t CO2] from CO2 transported in the transport network;

  • CO2 leakage events
  • Amount of CO2 [t CO2] transported in the transport network, which is emitted as the result of the failure of one or more components of the transport network;

  • CO2 installations
  • Amount of CO2 [t CO2] being emitted from combustion or other processes functionally connected to the pipeline transport in the transport network, monitored in accordance with the relevant sections of Annex IV.

    1. B.2.1Fugitive emissions from the transport network
    2. B.2.2Emissions from leakage events
    3. B.2.3Vented emissions